6.A.12. DISPLAYING TEMPERATURE AND PRESSURE:
Each time the machine switches on, immediately after the auto test, the display shows the opera-
tional message " Brasilia S.p.a.
water pressure in the boiler, expressed in atmosphere, time and date.
Note: The water temperature can be displayed by pressing MODE key: the display shows temperature,
expressed in Celsius degrees:
• To return to the operational message, press MODE.
PRESS MODE TO GO OUT OF PROGRAMMING MODE.
• The authorized service agent (installer or maintenance technician) must inform the manufacturer of POSSIBLE FAULTS or wear
which may affect the machine system's original safety.
• The user should promptly notify the authorized service agent of any FAULT or DEFECT. Only the authorized service agent may in-
stall, repair or perform maintenance on this equipment. Failure to comply with this instruction may void the equipment warranty or lead
to serious.
• If an alarm stops the machine, try to reset it by switching it OFF and ON again, to be sure that it is not simply due to a temporary sys-
tem failure.
• If POWER CORD is damaged, it must be replaced. Contact authorized service agent to prevent all risks. Failure to follow this instruc-
tion may result in damage to machine or electrocution.
TROUBLESHOOTING
** = Maintenance and reparations that can be performed only from authorized and specialized technician.
For the user: contact authorized service agent!
LED 4 switched on
(see touch key pad picture).
The group does not deliver
water and the pump is
noisy.
The group does not deliver
water.
The boiler is under pressure
but the group does not heat
up.
The boiler will not heat up.
The water level control pro-
vides water when it should
not and the level gauge light
is on.
REV. 2 04/2007
xxAtm
" Brasilia S.p.a.
7. TROUBLESHOOTING AND SOLUTIONS
CAUSES
• Group is blocked: In continuous delivery, if delivery is
not stopped manually using the STOP key within the time
limit of 120 sec.
• Should the turbine operate irregularly, the fault will be
signalled by the blinking of the block red LED on the
push-button pad of the group involved in the fault.
In this case delivery is not dosed, but if the operator does
not intervene manually with the STOP key, blocking oc-
curs when the time limit is reached.
• If the water level control solenoid valve remains open
for more than 90 sec., it is automatically switched off and
the fault is signalled by the block red LED blinking on all
the push-button pads.
• The water mains tap or the softener taps are shut.
• The water entry union filter is obstructed.
• The jet is obstructed
• The injector is obstructed
• (Only for versions with electronic dosing) the flowmeter
connection is obstructed.
• The solenoid valve will not open:
• The coil is not getting power.
• The coil is broken.
• The core is blocked.
• Air bleeding of the boiler did not occur during the water
heating stage.
• The water heating circuit is partially obstructed (except
lever machine).
• The heating element is broken.
• The heating element is not receiving power.
• The safety thermostat, pressure switch and main switch
are faulty.
• The level sensor/control centre electrical connection is
broken.
• The frame earthing/control centre electrical connection
is broken.
• The level sensor is dirty.
• The electronic control centre is defective.
hh:mm
dd-mm-yy ", made up of: name of the manufacturer,
xxx°C
hh:mm
To restart the machine, the power must be removed for at
least 5 sec. and then restored.
• Open the taps
• Dismantle and clean
• ** Remove the jet plug, check and clean or replace as nec-
essary
• ** Dismantle and clean, replace if necessary.
Note: check the regeneration of the softener resins.
• ** Dismantle and clean
• ** Check solenoid valve:
• Check and correct the electric connections.
• Replace.
• Preferably replace the complete solenoid valve.
• ** When cold check that the air vacuum valve is not blocked
shut. Replace if necessary.
• ** Check the group's inlet and outlet pipes and unions. Clean
and replace if necessary.
Note: check the regeneration of the softener resins.
• ** Replace.
• ** Check and replace the related components.
• ** Check and replace if necessary.
• ** Repair.
• ** Repair.
• ** Clean; when dismantling do not unthread it from the insu-
lator but remove it complete with the union.
• ** Replace.
dd-mm-yy "
SOLUTIONS
ENGLISH - 15