Brasilia OPUS Technical Manual page 31

Hide thumbs Also See for OPUS:
Table of Contents

Advertisement

Available languages

Available languages

1 – Connect the machine to the softener (n.12 pict.1):
• Connect the softener to the tap (n. 9 fig.1) using the pipe "11" (IN).
• Connect the pipe "13" (OUT) to the softener and insert the opposite extremity of pipe in a reservoir.
• Open the tap "9" and run the water through for a few minutes to clean the softener (cleaning of resins).
• Close the tap and connect the pipe "13" to the water inlet connector (n. 5).
2 - Connect the pipe "7" to the drain tray (n.6) and to the water main drain (n.8).
3 - Check the efficiency of the main drain pipe (mandatory fitted with a siphon).
Note: If the machine is fitted with a gas system, connect it to the tap (n° 17 fig.1) using the pipe (n° 16) and adjust it as instructed.
1 - Use only grounded electrical connection, complying with local electrical and building code requirement, and safety laws conforming
to your country of installation. The Installer/Manufacturer accepts NO responsibility for accidents due to non-compliance with local
safety and building code regulations.
2 - Ensure supply voltage is correct (see rating plate on back of machine).
3 - DO NOT use extensions/extension cord or fly-over connections for machine installation. The working environment may be exposed
to water and dampness which may affect insulation of system.
4 - Check security of power cord; it must be secure from physical damage.
5 - Connect power cord (n.3) to the mains line switch (n.2).
Note: The customer must provide for the machine's power supply, protecting the line with a suitable safety cut-out (life-saver).
PART. N°
1 - MAINS ELECTRICAL POWER SUPPLY
2 - MAINS LINE SWITCH
3 - POWER SUPPLY CORD
4 - ON/OFF SWITCH
5 - WATER INLET UNION
6 - DRAIN TRAY
7 - DRAIN PIPE
8 - MAIN DRAIN PIPE
9 - WATER MAINS TAP
10 - WATER MAINS SUPPLY LINE
11 - PIPE FROM WATER MAIN TO SOFTENER
12 - WATER SOFTENER
13 - WATER INLET PIPE
14 - MANUAL WATER FILLING PUSH-BUTTON OF
VALVES GROUP
15 - GAS SUPPLY PIPE (OPTIONAL)
16 - PIPE FROM GAS TAP TO GAS REGULATOR
(OPTIONAL)
17 - GAS TAP (OPTIONAL)
REV. 2 04/2007
3.C. WATER CONNECTION
3.D. ELECTRIC CONNECTION
Pict.1
• POWER CONNECTION OUTLET FROM ELECTRICAL MAINS
• SOCKET FOR ELECTRIC CONNECTION CABLE
• ELECTRIC CABLE OF CONNECTION
• ACTIVATES THE FUNCTIONS OF THE MACHINE
• TO CONNECT THE WATER INLET PIPE
• CARRIES THE WASTE WATER IN THE DRAIN PIPE
• WATER HOSE FROM DRIP TRAY
• WATER TUBING TO DRAIN
• TO OPEN OR CLOSE SOURCE WATER FLOW
• WATER SUPPLY FROM SOURCE
• WATER SUPPLY TO WATER MAINS SUPPLY LINE
• TO SUPPLY SOFTENED WATER
• WATER SUPPLY TO SOFTENER
• CARRIES THE WATER TO THE FLOWMETERS AND BOILER
• FOR THE ADMISSION OF THE GAS IN THE BURNER
• FOR THE LOADING OF THE GAS COMING FROM THE GAS-SYSTEM
• TO ENABLE OR DISABLE THE GAS FLOW
FUNCTION
ENGLISH - 6