Conventions Used In This Manual - NAPCO GEMINI GEM-P1664 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for GEMINI GEM-P1664:
Table of Contents

Advertisement

WI1423A 1/06
The displays shown on the previous pages will appear after a brief delay.
Direct Address Programming Example
Use
to toggle the cursor between the 4-digit address field and the data entry locations.
R
Example: Program Zones 6, 7 and 8 as Exit/Entry Follower Zones.
Enter the address directly using the number buttons.
DETERMINE THE DATA ENTRIES
The contents of the address will be read automatically, along with the feature name and programming information.
1. Referring to ZONE FEATURES in the Programming Worksheets that follow, Exit/Entry Follower for Zones 5
The cursor will advance to the data field. Enter the required data directly using the number buttons.
through 8 are located at address 0506, left digit. Circle
U
Press
to save the contents of each address.
2. Add the data values for Zones 6, 7 and 8: 2+4+8=14. From Tables 1 and 2, "14" (E) is entered as press
. The right digit (for Zones 1 through 4, none of which are Exit/Entry Follower Zones) is entered as a
G4
EXIT DIRECT ADDRESS PROGRAM MODE: When done, press
blank (•).
ZONE OPTION

CONVENTIONS USED IN THIS MANUAL

The Keypad Programming Worksheets in the back are provided as an address-programming reference to help the
EXIT/ENTRY FOLLOWER
installer modify his custom default program or to make
minor field alterations to an existing panel program. It is
recommended that the panel be uploaded to NAPCO's
PROGRAM THE DATA ENTRIES
PCD-Windows
software
programming and that the PCD-Windows error-check
1. Enter the panel's Dealer Security Code (Address 0500), then press
feature
be
utilized
to
the
button.
A
programming omissions or conflicts.
Note: Most of the addresses shown comprise two data
2. Answer NO (
entry locations, left and right digits.
NOTE: If you pass "ACTIVATE PROGRAM", scroll backward using the the
digits on the left data-display segment, and the right digit
on the right segment. For those addresses having only
3. Press the
button to enter the Address Program Mode. Address "0000" will display.
C
one programmable nibble, program the right segment
only; the left segment should display a blank (•).
4. Press
0506
3
Keep the Keypad Programming Worksheets on file for
cursor
will advance to the data field.
future reference.
5. Press
G 4
General Programming Steps
J
6. Press
to save.
1. Contact the central station to ascertain receiver
Address 1218 is now programmed with "E•".
format, data format, event codes, subscriber numbers
and telephone number(s).
7. Enter another 4-digit address to continue programming or press
2. Select the desired features by circling
respective
"address"
Programming Options and Worksheets for guidance
in selecting the "data" (1,2,4,8) to be entered into
those boxes.
3. Program the data entered in the boxes on the
worksheets into the respective addresses.
display will show the entry numerically, but will
display "0" for the number 10, and letters "B", "C",
"D", "E", and "F" for the numbers 11 through 15,
respectively. To program a 10, press
To program 11 through 15, press
through
G 5
NOTE: See the Direct Address Programming Example
on the previous page.
L
NAPCO Security Systems
ZONES
LEFT DATA VALUES
SUM = 14 (CIRCLE
ZN08
ZN07
ZN06
following
any
keypad
reduce
the
possibility
) to all questions until "ACTIVATE PROGRAM Y/N" is displayed; then press YES (
F
Program the left
to access Address 0506. The data for both digits will display and the
to enter an "E" in the left digit and press
boxes.
Refer
to
G 0
G 1
, respectively.
the data values for Zones 5–8.
to exit and resume normal keypad operation.
C
ADDRESS
)
0506
L
ADDR
ZN05
E
BLANK (•)
1
0460
DATA ENTRY SELECTIONS
(BINARY VALUE CIRCLED)
ENTER DATA
8
4
2
8
4
2
of
8
4
8
4
B
8
2
8
2
8
8
4
2
to enter a blank (•) in the right digit.
0
4
2
4
4
C
2
the
2
the
The
Table 1 (above). Determining data entry for a location
(each "nibble"). Numbers in parentheses indicate data for
selected
zones
Worksheets that follow).
.
X
GEM-P1664 Programming Instructions
ZONES
RIGHT DATA VALUES
R
ZN04
ZN03
ZN02
ZN01
8
4
2
ENTRY
PRESS
N
TOTAL
1
blank
0
1
1
2
1
2
3
3
button.
4
1
4
5
5
1
6
6
7
7
8
1
8
9
9
G 0
1
10
11
G 1
to exit and resume normal keypad
1
12
G 2
G 3
13
G 4
1
14
15
G 5
or
features.
(See
Page 23
1
KEYPAD
DISPLAYS
1
2
).
E
3
4
5
6
7
8
9
0
B
C
D
E
F
Programming

Advertisement

Table of Contents
loading

Table of Contents