SYST EM OUTPU T TI ME OU TS (AD D RESS 14 12 & 1 414 -14 16)
ADDRESS 1412
PGM2
Output
LEFT
RIGHT
Timeout (min.)
[Default = blank (•) blank (•)]
DATA ENTRIES
DELAY/
LEFT
RIGHT
TIMEOUT
blank (•) blank (•)
0 min.
blank (•)
1
1 min.
blank (•)
2
2 min.
blank (•)
3
3 min.
blank (•)
4
4 min.
blank (•)
5
5 min.
blank (•)
6
6 min.
1
blank (•)
16 min.
F
F
255 min.
DOWNL OAD /CALLBA CK OP TI ONS (ADDR ESS 2059 & 0526- 0545)
ADDRESS 2059
No. Rings
Before
LEFT
RIGHT
Pickup
blank (•)
[Default = blank (•) blank (•)]
CALLBACK
Telephone
0526 0527 0528 0529 0530 0531 0532 0533 0534 0535 0536 0537 0538 0539 0540 0541 0542 0543 0544 0545
Number
R
R
R
R
(Digits 1-20)
[Default = blank (•) for all digits 1-20]
CALLBACK TELEPHONE NUMBER: Enter telephone number to be used when downloading from a computer (see installation in-
structions WI1424 for more information).
1. Enter in right digit only (left digit is not used).
2. Enter up to 20 digits from left to right. NOTE: Leave trailing boxes blank (•). For a zero, press
3. Valid entries are: 1-9, B =
U
D
4. Press
or
to save.
PAGER FOR MAT OP TION S (ADD RESS 05 46 & 05 4 7)
ADDRESS 0546
Leading Digits for
Pager Format
LEFT
RIGHT
(1st Digit)
blank (•)
ADDRESS 0547
Leading Digits for
Pager Format
LEFT
RIGHT
(2nd Digit)
blank (•)
[Default = blank (•) blank (•)]
L
NAPCO Security Systems
ADDRESS 1414
Alarm
Output
LEFT
RIGHT
Timeout (min.)
[Default = 15 mins. = (blank) F]
1. Select delay/timeout (0-255 min.) from the table shown.
2. Enter in corresponding address locations above (left and right digits).
3. For a desired delay/timeout not listed do the following:
A. Choose a desired delay/timeout, ex: 20 min.
B. Divide it by 16
U
D
4. Press
or
to save.
OUTPUT TIMEOUTS: If a timeout of "0 min." is selected, then the output will remain active (ON)
until the system is reset or disarmed. For UL Residential Installations, the minimum timeout is 4
minutes. Not UL listed for Commercial Installations.
NUMBER OF RINGS BEFORE PICKUP: Enter the number of rings before automatic pickup by the control
panel when downloading from a computer (see installation instructions WI1424 for more information).
1. Enter in right digit only (left digit is not used).
2. Valid entries are: 3-9, 0 = 10, B = 11, C = 12, D = 13, E = 14, F = 15
NOTE: Default is 15 Rings. Dark shaded data shows option not available.
U
D
3. Press
or
to save.
ADDRESS 0526-0545 (RIGHT DIGITS 1-20)
R
R
R
R
R
*
#
button, C =
button, D = 3 sec. pause, E = Wait for dial tone, F = ignore location.
LEADING DIGITS FOR PAGER FORMAT:
However, for some pager services, this will cause the Pager's Voice Mail feature to activate. This option allows you
to program these digits to any number desired. A typical Pager report is "003 22 1234", where 3 is the Event, 22 is
the zone, and 1234 is the Subscriber ID number. For example, if the Leading Digits are programmed as "98", the
Pager report will now appear as "983 22 1234". NOTE: See CS Receiver Options to select Pager Format.
1. Enter in 1st and 2nd Leading Digits in right digit only (left digit is not used) as shown.
2. Valid entries are: 0-9.
U
D
3. Press
or
to save.
ADDRESS 1415
Pulse Alarm
Output
LEFT
RIGHT
Timeout (min.)
[Default = 15 mins. = (blank) F]
1 Quotient
16 20
16
4 Remainder
R
R
R
R
R
R
In Pager Format reporting, the message typically begins with "00".
X
GEM-P1664 Programming Instructions
ADDRESS 1416
PGM1
Output
LEFT
Timeout (min.)
[Default = blank (•) blank (•)]
Left Digit
Right Digit
R
R
R
R
R
G0
.
Page 25
RIGHT

Advertisement

Table of Contents
loading

Table of Contents