Download Print this page
NAPCO WI850A GEM-P800 Installation Instructions Manual

NAPCO WI850A GEM-P800 Installation Instructions Manual

Hide thumbs Also See for WI850A GEM-P800:

Advertisement

Quick Links

®
GEM-P800
Control Panel/Communicator

Installation Instructions

© NAPCO 1997
WI850A 8/97

Advertisement

loading

Summary of Contents for NAPCO WI850A GEM-P800

  • Page 1: Installation Instructions

    ® GEM-P800 Control Panel/Communicator Installation Instructions © NAPCO 1997 WI850A 8/97...
  • Page 2 Amityville, New York 11701 Enhanced Communicator Features ....19 Wireless ............20 For Sales and Repairs, call Toll Free: (800) 645-9445 Downloading.............21 Dealer Programming ........22 System Troubles ..........23 For Technical Assistance, Contact the NAPCO Toll Free Helpline Troubleshooting..........25 (800) 645-9440 GEM-P800 WIRING DIAGRAM ......27...
  • Page 3 Max # of compatible 7UDQVIRUPHU DQG %DWWHU\ 2-wire smoke detectors : ----------- 10 Max Keypad wire length : --------- 1000’ total wire length Required Transformer: --------------NAPCO TRF12 OR BASLER 16.5 VAC 20VA 0LVFHOODQHRXV Required Battery: ---------------------12V 4 AH Rechargeable Change Battery every 5 years or as required Housing Dimensions : -------------- 11"...
  • Page 4 WI850A GEM-P800 Installation Instructions 8/ &RPSDWLEOH 6PRNH 'HWHFWRUV 2UGHULQJ ,QIRUPDWLRQ GEM-P800 Compatible Smoke Detectors GEM-P800 8 zone Control Panel with 2-wire fire 4-Wire 2-Wire Smoke Detector GEM-RP8 Keypad Smoke Detector Smoke Detector Base Zone Doubling Resistors (2.2K & 3.9K) OI219...
  • Page 5 loaded using PCD2000 Software running 4. Site-Initiated (PCPreset & 3URJUDPPLQJ WKH 3DQHO PCPreset. For Site Initiated Downloaded, see 5. Automatic Downloading (Using PCPreset) Refer to GEM-P800 Programming Instructions (WI851) Auto Download ID Number [93]. Defaulting the Panel Local Downloading 1. Remove power from the panel. Wire as shown in Figure 1.
  • Page 6 WI850A GEM-P800 Installation Instructions ,QVWDOODWLRQ :LULQJ For increased protection, additional detectors should be installed in areas other than those required, such as the dining room, bedrooms Mounting the Panel Grounding the Panel and utility room. Heat detectors, rather than Mount the Panel close to an unswitched AC...
  • Page 7 Fire Zone Wiring Keypad Sounder Wire the Fire Zone as shown in the Wiring Diagram in the back of this manual. An EOL NAPCO’s EZ Zone Doubling is simple. Each QUICK BEEPS resistor must be installed, even if the Fire Zone terminal has 2 zones, use an E (2.2 K) type Zone...
  • Page 8 WI850A GEM-P800 Installation Instructions Keyfob have been programmed for Full Set Keypad LEDs 3DQHO 2SHUDWLRQ [81-84]. To arm the system with all zones pro- tected press the key. Press and hold the ARMED LED DEFINITION Arming (System ON) Armed key for 1.5s to fully set the system...
  • Page 9 Tone. Enter a valid Arm/Disarm code, then Home Bypassing a zone press . If a valid Arm/Disarm code is entered, Press the key, then the zone number to be Exit/Entry Zone is not violated Zones selected as Home/Away with Delay bypassed.
  • Page 10 WI850A GEM-P800 Installation Instructions of 1234, program the 4-digit User 1 Code through While in User Program Mode the Armed, Status matically every *24 hours to ensure proper bat- Dealer Programming [95]. User 1 Arm/Disarm System Trouble LEDs will continue to tery operation under load.
  • Page 11 Keypad will chime on any zone that has not been SIGNAL STRENGTH KEYPAD SOUNDER line and the Control Panel phone line. When selected as an Exit/Entry Follower Zone , Home/ 3 or less ready, tell the installer to arm, then disarm. S BEEP Away with Delay Zones, or 24 Hour Zone .
  • Page 12 WI850A GEM-P800 Installation Instructions from a Keyfob. Program the Keyfob AUX Remote Activation =RQH )HDWXUHV Using NAPCO’s Quickloader Software 1 or AUX 2 button for Full Set [81-7]. (Version 3.26 or higher), follow the instruc- [00]Exit/Entry Zones tions below: Delay allows exit and entry through an Exit/...
  • Page 13 cally be unbypassed and any subsequent [07]Burg (Steady) Output [11]Entry Delay violations of the zone will cause an alarm Delay time permits entry through Exit/Entry Enables the Bell Output on a zone trip for condition. each zone selected. The Bell Output will Zone(s) after the system is armed without remain ON for the length of time pro- setting off an immediate alarm.
  • Page 14 WI850A GEM-P800 Installation Instructions Additional Programming required: [18]Test Timer Offset [15]Line Cut Time-to-Fail Select reporting to Telco 1 [36-3] or Telco 3 Enter the time, in hours, that a Test Timer Enable this feature by programming the de- [56-3]. will be reported after Dealer Mode has been lay time required to declare a line cut failure.
  • Page 15 output for 5 seconds using the [22]Miscellaneous Features 1 [25]Programmable Output Features 3 (1) Abort Delay - Program to allow a 15 command. (1) AC Fail - Program to activate the PGM on second Delay (except 24 Hour Zones ) after (3) Follow Keypad Sounder - The follow- the loss of AC.
  • Page 16 WI850A GEM-P800 Installation Instructions 7HOHSKRQH 1XPEHU  3URJUDPPLQJ [33]Receiver Options [36]System Reporting, Telco 1 (1) 2300 Hz HS/Kissoff - Select 2300 Hz (1) Keypad Fire - Program to activate a Handshake and Kissoff. [30]Subscriber ID Number Keypad Fire report ( (2) Sumcheck - Only used for the following For 4/2 format enter a 4 digit number.
  • Page 17 (2) Battery Restore - Program to activate a [42]Receiver Format (Telco 2) [46]Communicator Features 2 Battery Restore report. Select the format that will be used to report (1) No Dial Tone Detection - Program to (3) Trouble Restore - Program to activate a for Telco 2 (Backup reporting).
  • Page 18 WI850A GEM-P800 Installation Instructions Pager Alarm data is the same as 4/2 format [49]Pager Options 3/1 format - Sends only the report Code and with the exception that the 2 digit Report (1) Skip Alarm Data - Once pager format is does not append it with the zone number.
  • Page 19 [63]System Report Codes (QKDQFHG &RPPXQLFDWRU )HDWXUHV :LUHOHVV Program a 2-digit report code for Keypad Fire, Keypad AUX, Keypad Panic, Test Up to two receivers can be wired to the [67]Telephone Number 1 Timer, AC Fail, Low Battery, Trouble and GEM-P800. Each wireless transmitter can (1) Opening After Alarm (Cancel Code) - Fire.
  • Page 20 WI850A GEM-P800 Installation Instructions Find Mode) or saved to the LOG (see Signal Enter the RF ID# and AUX 1 and AUX 2 buttons on the Keyfob are pressed. Strength Logging Mode - pg. 11). options for each Keyfob. Press the button to turn the Bell OFF.
  • Page 21 are pressed when the system is armed with to initiate a 2 hour test period. The signal 'RZQORDGLQJ Exit/Entry Follower Zones or Home/Away strength information for all supervisory sig- with Delay Zones that have been bypassed. nals received over a two hour period will be [90]Callback Telephone Number saved to the LOG.
  • Page 22 WI850A GEM-P800 Installation Instructions played on the Fire LED. Fire Trouble is 5. Enter Standby Mode by entering [95]User 1 Code indicated by a steady Fire LED. The 1st User code is a program code as The Computer is now in STANDBY well as an Arm/Disarm code.
  • Page 23 EXAMPLE Audible System Trouble Indication - For all LOW BATTERY SYSTEM TROUBLE DISPLAY 6\VWHP 7URXEOHV system troubles, except when the only system Enter to enter System Trouble mode Use the System Trouble chart on the following trouble is the loss of AC, the keypad will beep and determine the specific trouble.
  • Page 24 WI850A GEM-P800 Installation Instructions 6\VWHP 7URXEOHV Keypad Beeps or Zone LED System Trouble Cause/Action Condition SYSTEM Flashes This trouble will occur if AC power is not present. Ensure that the transformer is connected to an unswitched power source. 1 Beep...
  • Page 25 Zones programmed as Exit/Entry 6. The PGM Output Pulses in Alarm. 7URXEOHVKRRWLQJ Followers When the PGM lug of the control panel is 2. Zones programmed for 24 Hour Pro- programmed for an Armed indication it also 1. The bell output drops to about 3 volts in tection.
  • Page 26 WI850A GEM-P800 Installation Instructions 8. How do I remove Keypad Sounder on If using internal reed, make sure J1 is 12. No Keypad Chime? Alarm? cut and both Point 1 and Point 2 termi- The keypad sounder is turned off with the The keypad sounder follows the Burg Out- nals are jumped out.
  • Page 27 +10 -11 +12 -13 16 VAC 20 VA FIRE FIRE BELL +PWR GND GREEN RING RING 2.2K TRANSFORMER TELCO PHONE NAPCO TRF12 REMOTE BUS (OR EQUIVALENT SEE WI850). Class 2 Transformer. GOLD Zone DO NOT Doubling RED RED connect to To RJ31X...
  • Page 28 NAPCO neither assumes, nor authorizes any other person purporting to act on its behalf to modify, to change, or to assume for it, any other warranty or liability concerning its products. In no event shall NAPCO be liable for an amount in excess of NAPCO's original selling price of the product, for any loss or damage, whether direct, indirect, incidental, consequential, or otherwise arising out of any failure of the product.