Gem-Rp2Ase2/Gem-K2As Keypad - NAPCO GEMINI GEM-P1664 Programming Instructions Manual

Control panel/communicator
Hide thumbs Also See for GEMINI GEM-P1664:
Table of Contents

Advertisement

Page 6
GEM-RP2ASe2/GEM-K2AS Keypad Easy Program Menu
Enter the Dealer Security Code (default = 456789) for a new panel or enter your custom Dealer Program Code if
GEMINI
SYSTEM ARMED
programmed. Press the PRIOR/NO button repeatedly until "TURNON/PROG" is displayed. NOTE: If you pass "TURNON/
ENT A1
ENT A1
01/01/97 12:00AM
PROG", you can scroll back by pressing
NEXT/YES
A
1 2
3
E
D
PRIOR/NO
B
4
5 6
F
each of the following steps, press
AREA
C
7 8 9 0
G
COMPUTERIZED SECURITY SYSTEM
R
PRIOR/NO button to go backwards,
Total Number of Zones in Area 1 (Appears for New Panel Only)
Ent A 1
Directly enter the total number of zones to be programmed for Area 1. Valid entries are from 01 to 64.
Directly enter the total number of zones, including leading zeros. Use number buttons
#ZnXX
9
zones), and will automatically round up to the next group of 4. For example, if you enter 18, it will
(Direct Entry)
automatically convert this to 20 zones. Press
NOTE: If you are programming a 2, 3 or 4 Area system, enter the total number of zones required for Areas 1-4. The Direct Address
Program Mode can then be used to remove zones from Area 1 and place them in the other areas.
Programming a Wireless-Only system, or using Wireless-Only on Zones 9-64, enter the total number of zones in system. Enter the
transmitter points in the RF Transmitter section of the Easy Menu Driven Programming Mode.
Panel Zone Doubling (Appears for New Panel Only)
Zn Db l
If the total number of zones in Area 1 entered was 16 or greater, press the NEXT/YES button to
effectively double the capacity of the control panel's hard wired zones from 8 to 16. The 16 zones will re-
main EOL terminated zones, but will be designated for Normally Closed devices only. The terminal for
Enabl ?
Zone 1 will now support Zones 1 and 9 with the use of the supplied EZ Zone Doubling
supplied. (Refer to Wiring Diagram and Installation Instructions). If Panel Zone doubling is not desired,
Y/N
press the PRIOR/NO button.
(Press YES or NO)
Fire Zones in Area 1 (Appears for New Panel Only)
Ent F r
Enter the zone number of any zones which are to be used as Fire Zones (both 2-wire, 4-wire or wireless).
Valid entries are from 01 to 64. Directly enter each zone number, including leading zeros, and press
Zn#XX
to save, and then repeat for any additional zone(s). Press NEXT/YES button to proceed.
NOTE: If you are programming a multiple Area system, enter all the zone numbers required for Areas 1
(Direct Entry)
through 4. The Direct Address Program Mode can then be used to remove zones from Area 1 and place
them in the other areas. See Zone Options.
2-Wire Fire Zones in Area 1 (Appears for New Panel Only)
Ent2W F
Enter the zone numbers of any Fire Zones (from previous question) which are to be used with 2-wire
smoke detectors. The only valid entries are 07 and 08. Directly enter each zone number, including
Zn#XX
leading zeros. Press
have been designated as Fire Zones in the prior question may be programmed as 2 Wire Fire zones.
(Direct Entry)
Press the NEXT/YES button to proceed. NOTE: JP3 must be set to "2-WF" position for 2-wire fire zones
(refer to Installation Instructions).
Local or Central Station Reporting System (Appears for New Panel Only)
Repor t
Press the NEXT/YES button for all zones to report; press the PRIOR/NO button for no zones to report
(LOCAL SYSTEM).
all Z n
Y/N
(Press YES or NO)
Exit/Entry Zones in Area 1 (Appears for New Panel Only)
EntEE 1
Directly enter the zone number of any zones which are to be used as Exit/Entry zones. Valid entries are
from 01 to 64. Directly enter each zone number, including leading zeros. Use number buttons
Zn#XX
through
additional zone(s). Press the NEXT/YES button to proceed.
(Direct Entry)
NOTE: Chime will automatically be programmed for all E/E zones. If you are programming a multiple
area system, enter all exit/entry zone numbers required for Areas 1-4. The Direct Address Program Mode
can then be used to remove zone from Area 1 and place them in Areas 2, 3 or 4. See Zone Options.
X
GEM-P1664 Programming Instructions
. Press the NEXT/YES button to enter the Dealer Program Mode. In
B
to jump to the next screen, the NEXT/YES button to go forwards, the
R
U
to save and
. NOTE: Press
for a zero. The system is based on groups of 4 zones each (after the first 8
0
U
to save, and then repeat for any additional zone(s). NOTE: Only zones which
. NOTE: Press the
9
0
twice to exit at any time.
C
U
to save. Press the NEXT/YES button to proceed.
U
button for a zero. Press
to save and then repeat for any
L
WI1423A 1/06
through
1
See Zone Options.