Page 24
SYST EM DE LAY S & TIM EOU TS (ADD RESS 00 0 0-0 002, 14 1 3, 14 17 , 20 50 & 2 05 5)
ADDRESS 0000
EXIT
ENTRY
DELAY
DELAY 1
LEFT
RIGHT
(sec.)
(sec.)
[Default = 3 C]
DATA ENTRIES
DELAY/
LEFT
RIGHT
TIMEOUT
blank (•) blank (•)
0 sec.
blank (•)
F
15 sec.
1
E
30 sec.
2
D
45 sec.
3
C
60 sec.
5
0
90 sec.
7
8
120 sec.
EXIT/ENTRY DELAYS: Apply only to zones programmed with the following options "Exit/
Entry 1, Exit/Entry 2, Exit/Entry Follower". For UL Installations, the maximum exit delay
F
F
255 min.
is 60 seconds and the maximum entry delay is 45 seconds. NOTE: Sensor Watch
Time Options are similar to above table, except in hours.
PROGRAMMING TIMEOUTS: Either use the tables provided or calculate your own timeout
using the steps indicated. WARNING: Timers have uncertainty of +/-1sec, so a "time" of 1
second may actually timeout IMMEDIATELY.
SYSTEM DE LAY S & TIM EOU TS (ADDRESS 1418 & 1419)
CHIME
ADDRESS 1418
TIME
LEFT
(¼sec.)
[Default = 2 sec. = blank (•) 8]
CHIME TIMEOUT OPTIONS
DATA ENTRIES
TIMEOUT
LEFT
RIGHT
blank (•)
blank (•)
(0) ¼sec. = 0 sec.
blank (•)
2
(2) ¼sec. = ½ sec.
blank (•)
3
(3) ¼sec. = ¾ sec.
blank (•)
4
(4) ¼sec. = 1 sec.
blank (•)
5
(5) ¼sec. = 1.25 sec.
blank (•)
6
(6) ¼sec. = 1.5 sec.
blank (•)
7
(7) ¼sec. = 1.75 sec.
blank (•)
8
(8) ¼sec. = 2 sec.
F
F
(255) ¼sec. = 63.25
1. Select delay/timeout from the table shown.
2. Enter in corresponding address locations above (left and right digits).
3. For a desired delay/timeout not listed do the following:
A. Choose a desired delay/timeout, ex: 20
B. Divide it by 16
U
D
4. Press
or
to save.
X
GEM-P1664 Programming Instructions
ADDRESS 0001
ENTRY
DELAY 2
LEFT
RIGHT
(sec.)
[Default = 1 E]
1. Select delay/timeout (0-255 sec.) from the table shown.
2. Enter in corresponding address locations above (left and right digits).
3. For a desired delay/timeout not listed do the following:
A. Choose a desired delay/timeout, ex: 20 sec.
B. Divide it by 16
U
D
4. Press
or
to save.
AC Fail
Report Delay
RIGHT
(min.)
[Default = 60 mins. = 3 C]
AC FAIL REPORT DELAY OPTIONS
DATA ENTRIES
LEFT
RIGHT
blank (•)
blank (•)
blank (•)
1
blank (•)
2
blank (•)
3
blank (•)
4
blank (•)
5
blank (•)
6
blank (•)
7
F
F
1 Quotient
16 20
16
4 Remainder
ADDRESS 0002
PGM2 Output
Access Cntrl
LEFT
RIGHT
Timeout (sec.)
[Default = 1 E]
[Default = blank (•) blank (•)]
1 Quotient
Left Digit
16 20
16
4 Remainder
Right Digit
ADDRESS 1419
DEFAULTS: The defaults shown on this
LEFT
RIGHT
page and on the following pages are
automatically set after exiting the Easy
Menu Driven Mode.
TIMEOUT
blank (•)
1
2
3
4
5
6
PROGRAMMING STEPS:
7
1. Lookup desired Programming Option by
Address Location (highlighted in black).
255 min. = 4 Hr., 30 min.
2. Select the programming option data entry
from the tables shown.
3. Enter the selected data entry in the boxes
shown.
4. For more information on a programming
option refer to the Glossary at the end of
Left Digit
this manual.
Right Digit
WI1423A 1/06
ADDRESS 1413
ABORT
DELAY
LEFT
RIGHT
(sec.)
Sensor Watch
Time
(Hrs.)
[Default = 24 HRS = 1 8
Report Cancel
Window
(min.)
[Default = zero minutes =
blank (•) blank (•)]
ADDRESS LOC.
Program
LEFT
RIGHT
Option
ENTER DATA
L
NAPCO Security Systems
ADDRESS 1417
LEFT
RIGHT
[Default = 1 E]
ADDRESS 2050
LEFT
RIGHT
ADDRESS 2055
LEFT
RIGHT