NAPCO GEMINI GEM-P1664 Programming Instructions Manual page 39

Control panel/communicator
Hide thumbs Also See for GEMINI GEM-P1664:
Table of Contents

Advertisement

WI1423A 1/06
AREA BELL C ON TRO L OPTIONS (ADDRESS 1481-1484)
PGM1 Output Turns Off upon Disarm
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
RESERVED
OUTPUT TURNS OFF UPON DISARM: Select options for any of the 4 Outputs.
1. Select the desired option by circling
2. Add the data values (ex: F=15=(1+2+4+8) from the selected options. See page 23).
3. Enter in right digit address location. NOTE: Dark shaded data value box shows option not available.
U
D
4. Press
or
to save.
OUTPUT TURNS OFF UPON DISARM:
Select options for any of the 4 Outputs. By default, the ability to turn off an output upon disarm is not allowed. For example, the abil-
ity to silence an Area 1 through Area 4 output via an Area 1 keypad is not enabled by default. To enable selected area output con-
trol, enter the number (1,2,3,4) accordingly. For example, if you wish to grant an Area 1 keypad the ability to turn off an Area 2
PGM2 output, enter "2" in Address 1485.
Enter digit in address location. NOTE: Dark shaded data value box shows option not available. Press
L
NAPCO Security Systems
LEFT DATA
PGM1 Output Turns Off upon Disarm
VALUES
ADDRESS 1481
)
(CIRCLE
LEFT DIGIT (SUM
1
OF DATA VALUES)
2
4
8
[Default = blank (•) one (1)]
LEFT DATA
PGM1 Output Turns Off upon Disarm
VALUES
ADDRESS 1482
)
(CIRCLE
LEFT DIGIT (SUM
1
OF DATA VALUES)
2
4
8
[Default = blank (•) one (1)]
LEFT DATA
PGM1 Output Turns Off upon Disarm
VALUES
ADDRESS 1483
)
(CIRCLE
LEFT DIGIT (SUM
1
OF DATA VALUES)
2
4
8
[Default = blank (•) one (1)]
LEFT DATA
PGM1 Output Turns Off upon Disarm
VALUES
ADDRESS 1484
)
(CIRCLE
LEFT DIGIT (SUM
1
OF DATA VALUES)
2
4
8
[Default = blank (•) one (1)]
the data values for right digit only (left is not used).
RIGHT DATA
VALUES
(CIRCLE
RIGHT DIGIT (SUM
OF DATA VALUES)
(1)
RIGHT DATA
VALUES
(CIRCLE
RIGHT DIGIT (SUM
OF DATA VALUES)
(1)
RIGHT DATA
VALUES
(CIRCLE
RIGHT DIGIT (SUM
OF DATA VALUES)
(1)
RIGHT DATA
VALUES
(CIRCLE
RIGHT DIGIT (SUM
OF DATA VALUES)
(1)
X
GEM-P1664 Programming Instructions
Page 39
Disarming Area 1
)
Area 1 PGM1 Output Silenced
1
Area 2 PGM1 Output Silenced
2
Area 3 PGM1 Output Silenced
4
Area 4 PGM1 Output Silenced
8
Disarming Area 2
)
Area 1 PGM1 Output Silenced
1
Area 2 PGM1 Output Silenced
2
Area 3 PGM1 Output Silenced
4
Area 4 PGM1 Output Silenced
8
Disarming Area 3
)
Area 1 PGM1 Output Silenced
1
Area 2 PGM1 Output Silenced
2
Area 3 PGM1 Output Silenced
4
Area 4 PGM1 Output Silenced
8
Disarming Area 4
)
Area 1 PGM1 Output Silenced
1
Area 2 PGM1 Output Silenced
2
Area 3 PGM1 Output Silenced
4
Area 4 PGM1 Output Silenced
8
U
D
or
to save.