Interior (Stay) Bypass Zones in Area 1 (Appears for New Panel Only)
EntFo l
Directly enter the zone number of any zones which are to be used as Interior Follower Zones. Valid entries are
from 01 to 64. Directly enter each zone number, including leading zeros. Use number buttons
Zn#XX
9
NEXT/YES button to proceed. NOTE: All Interior Follower zones will also be automatically programmed as "Exit/
(Direct Entry)
Entry Follower" and "Power Up Delay" zones. If you are programming a multiple Area system, enter the total
number of zones required for Areas 1-4. The Direct Address Program Mode can then be used to remove zones from Area 1 and place them in
Areas 2, 3 or 4. See Zone Options.
24 Hour Zones in Area 1 (New Program Only)
Ent24 H
Zn#XX
(Direct Entry)
Chime Zones in Area 1 (New Program Only)
EntCZ 1
Zn#XX
(Direct Entry)
NOTE: A chime time of 2 seconds will be automatically programmed.
Chime 2 Zones in Area 1 (New Program Only)
EntCZ 2
Zn#XX
(Direct Entry)
NOTE: A chime time of 2 seconds will be automatically programmed.
Exit/Entry2 Zones in Area 1 (New Program Only)
EntEE 2
Zn#XX
NOTE: An Exit/Entry 2 Entry Time of 30 sec. will automatically be programmed.
(Direct Entry)
50 mS Loop Response Zones (New Program Only)
Ent50 m
Zn#XX
(Direct Entry)
AUX Output Activated on Alarm Zones (New Program Only)
EntAu x
Zn#XX
NOTE: An Aux Output Timeout of 15 Minutes will automatically be programmed.
(Direct Entry)
Sensor Watch Zones (New Program Only)
Ent S W
Zn#XX
NOTE: A Sensor Watch Time of 24 hours will automatically be programmed.
(Direct Entry)
Keypad Sounder On Alarm Zones (New Program Only)
EntKP S
Zn#XX
(Direct Entry)
L
NAPCO Security Systems
. NOTE: Press
for a zero. Press
0
Enter the zone numbers of zones to be used as 24 Hour zones.
Valid entries are from 01 to 64. Directly enter each zone number, including leading zeros.
U
Press
to save and repeat for any additional zone(s); press the NEXT/YES button to proceed.
Enter the zone numbers which are to be used as Chime Zones.
Valid entries are from 01 to 64. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
Enter the zone numbers which are to be used as Chime 2 Zones.
Valid entries are from 01 to 64. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.
Chime 2 zones give a distinct pulsating tone when zone is faulted.
Enter the zone numbers of zones to be used as Exit/Entry 2 zones.
Valid entries are from 01 to 64. Directly enter each zone number, including leading zeros.
U
Press
to save and repeat for any additional zone(s); press the NEXT/YES button to proceed.
Enter the zone numbers of zones to be have a 50mS loop response. Note: Time can also be adjusted
via address 2280. Note: 750mS is required for Loop Response time in UL installations.
Valid entries are from 01 to 08. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.
Enter the zone numbers of zones to activate the PGM2 output upon alarm.
Valid entries are from 01 to 64. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.
Enter the zone numbers of zones to be Sensor Watch zones.
Valid entries are from 01 to 64. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed.
Enter the zone numbers of all zones to activate the Keypad Sounder upon alarm.
Valid entries are from 01 to 64. Directly enter each zone number, including leading zeros.
U
Press
to save and then repeat for any additional zone(s), press the NEXT/YES button to proceed.
U
to save and then repeat for any additional zone(s). Press the
X
GEM-P1664 Programming Instructions