GBC TITAN 165 Instruction Manual page 22

Hide thumbs Also See for TITAN 165:
Table of Contents

Advertisement

Calibrations
d) Use the small flat tip screw driver to remove the
contact block to the emergency stop button.
e) With a #2 phillips screw driver, remove the rear
panel cover.
f) Disconnect the upper IR sensor and connect the
calibration box.
g) Depress and hold down the MEAS button, if the
display reading is 248
step. If not, release the MEAS button and adjust
SVR1 to obtain a display reading of 248
o
C ).
Page 2 - 6
TO P an d B O T AD J.
( S V R 1 & S V R 2 )
U p pe r a nd low e r IR
se n so r c o nn e cto rs
o
o
F ( 120
C ) goto next
o
F ( 120
Titan 165/ 110 Technical Service Manual
IN F O R M AT IO N
C lockw ise to increase,
counterclockw ise to decrease.
h) Disconnect the calibration box and reconnect the
upper IR sensor.
i) Disconnect the lower IR sensor and connect the
calibration box.
j) Depress and hold down the MEAS button, if the
display reading is 230
step. If not, release the MEAS button and adjust
SVR1 to obtain a display reading of 230
o
C ).
k) Disconnect the calibration box and reconnect the
lower IR sensor.
l) Replace the rear panel cover, the control side
cabinet, the unwind brake handles and the lift
handle.