Remote Console Connection Problems - IBM E Server i Series Manual

Operations console, access for windows
Hide thumbs Also See for E Server i Series:
Table of Contents

Advertisement

13. Click OK. Click OK.
14. Do a Connect.
15. At the server's control panel enter a function 65 (you need to take the server
16. The server's control panel may display D1008065 after a little while. Also, in
17. At the server's control panel enter a function 66. You may get D1008066. Do
18. Using uppercase, type NEGOTIATE 1 in the HyperTerminal window. Press

Remote console connection problems

When setting up your remote console you may encounter problems connecting.
Possible troubleshooting solutions include:
106
iSeries: iSeries Access for Windows Operations Console
v Echo typed characters locally
v Append line feeds to incoming line ends
v Wrap lines that exceed terminal width
to a known state).
Note: You may need to enter a function 25 and 26 in order to have access to
the upper functions.
the HyperTerminal window, you may get some data.
not worry if the refernce code does not post. Also, in the HyperTerminal
window, you may get some data.
Enter. The HyperTerminal data window displays 115200.
Note: If nothing is returned, repeat NEGOTIATE 1.
If a speed is returned, you had data exchanged in both directions and have
full connectivity. If Operations Console will not connect, more than likely you
have a setup problem on the client side.
If a speed was not returned, it is most likely that the problem is on the client
PC. You might try powering off the PC, power it back on, and repeat the test.
Or attempt to connect the console again. In rare cases the server may need to
be IPLed. For the best results it is recommended you do the following, in
sequence:
a. Power off the server.
b. Power off the PC.
c. Power on the PC.
d. Start a connection for the console.
e. Power on the server.
If the above process fails to solve your connection problem, you need to
contact your service provider for further assistance.
Remote console through dial-up fails to connect to local console
Solutions to a problem that occurs when a remote console modem fails to
establish a connection with a local console.
Local console name mismatch when remote console connects to the local
console
Reasons for a possible console name mismatch when the remote console
connects to the local console.

Advertisement