10. Press F3 to return to the DST main menu.
The system is now configured for use by Operations Console local console on a
network.
If you do not plan to use the local console directly attached configuration as an
alternate console, do not remove or move it or its adapter at this time. You may
need it to debug a problem. Ensure the configuration for the local console directly
attached is not in a Connecting status so that the next initial program load (IPL)
will not select it as the console device.
The iSeries system value QAUTOCFG must be set to ON. Use one of the
following to verify or set this system value on the iSeries server:
v Use the WRKSYSVAL QAUTOCFG OS/400 command.
v During a manual IPL, in the IPL Options window, select Y for Set major system
Continue with Configure the PC to use the new console type.
Migrate the console from a local console directly attached to a
local console on a network in a secondary partition
To migrate Operations Console with a local console directly attached to a local
console on a network (LAN), follow these steps on the server using the existing
console:
Note: If you need to add or move adapters to satisfy the hardware requirements
22
iSeries: iSeries Access for Windows Operations Console
If you get a message stating that the LAN adapter was not found, you have
not satisfied the hardware requirements for Operations Console.
6. Press F11 to configure the adapter.
7. Enter the appropriate network data.
8. Press F7 to store the data.
9. Press F14 to activate the adapter for use by Operations Console.
options. Then, for Enable automatic configuration, select Y.
for Operations Console, do this work prior to starting these migration steps.
Do not move or remove the twinaxial adapter from its current input and
output processor (IOP) at this time.
1. Access Dedicated Service Tools (DST).
2. Select Work with System Partitions.
3. Select Work with partition configuration.
4. Choose Select Console Resource (option 7) on the secondary partition.
5. Press F9 to Change capability filter.
6. Select Any Console (option 4).
7. To select the IOP that will support the twinaxial console, do one of the
following:
v If the adapter to be used for the local console on a network is under the
same IOP as the local console directly attached adapter, the console IOP is
already correctly tagged. Go to step 9.
v If the adapter to be used for local console on a network is under a different
IOP than the currently configured console, place a 1 in front of the IOP to
select it as the console IOP.
v Put a 2 in front of the previous console IOP to tag it as the alternate console
IOP.