8. Verify that the IOP containing the adapter for the local console directly
attached is tagged as the alternate console.
Attention: If the current console IOP is not selected as the alternate console
IOP, you may not be able to finish configuration. Also, if the correct IOP to be
used for the new console type is not correctly tagged you may have to use the
Operations Console to debug any problems you might encounter.
9. Press F3 to exit to the DST main menu.
10. Select Work with DST environment.
11. Select System Devices.
12. Select Console mode.
13. Select Operations Console (LAN):
a. The Verify Operations Console Adapters window appears. This is the
resource found by the system to be used for you LAN connections. If you
receive the message No valid LAN adapter available you did not satisfy
the hardware requirements for Operations Console. If so, use F3 to exit to
the DST main menu, then, start this topic again at step 1.
b. Press F11 to configure the adapter.
c. Enter the appropriate network data.
d. Press F7 to store the data.
e. Press F14 to activate the adapter for use by Operations Console.
14. Press F3 until you return to the DST main menu.
The server is now configured for use by Operations Console. If you do not plan to
use the local console directly attached configuration as an alternate console, do not
remove or move it or its adapter at this time. You may need it to debug a problem.
Ensure the configuration for the local console directly attached is not in a
Connecting status so that the next initial program load (IPL) will not select it as
the console device.
The iSeries system value QAUTOCFG must be set to ON. Use one of the
following to verify or set this system value on the iSeries server:
v Use the WRKSYSVAL QAUTOCFG OS/400 command.
v During a manual IPL, in the IPL Options window, select Y for Set major system
options. Then, for Enable automatic configuration, select Y.
Continue with Configure the PC to use the new console type.
Configure the PC to use the new console type when migrating
from a local console directly attached to a local console on a
network
To migrate Operations Console with local console directly attached to a local
console on a network (LAN), you must configure the PC to use the new console
type.
Follow these steps on the PC:
1. Disconnect the current console connection. To disconnect, do the following:
a. Select the configuration name (under iSeries Connection). This is the name
that Operations Console uses to refer to a specific iSeries server.
b. From the Connection menu, click Disconnect. The connection status shows
Disconnecting.
c. Wait for the status to show Disconnected.
Chapter 3. Plan for Operations Console