c. Using the Down button, decrement the data to 65, and then press the
Enter button. The system will respond with 65 00. After processing the
function the system will respond with a D1008065. Repeat this step so
that you have entered 7 function 65s. You will have 5 minutes to
complete this task. When the seventh 65 is entered and if it is found
that greater than 5 minutes have elapsed, the reset will not be done
and the count will return to zero.
– For secondary partitions follow these steps using the console on the
primary partition:
a. Access Dedicated Service Tools (DST).
b. Select Work with system partitions.
c. Select Work with partition status.
d.
Enter a 65 on the line used for the partition to be reset, then press
Enter.
e. Repeat this step so that you have entered 7 function 65s. You will have
5 minutes to complete this task. When the seventh 65 is entered and if
it is found that greater than 5 minutes have elapsed the reset will not
be done and the count will return to zero.
3. Use the following information to help determine your progress and success
of the reset:
Note: If your system uses the new double-row Function/Data display
control panel, you may have to perform a function 11 in order to
display the results (D1008065). Allow at least 15 seconds for the initial
function 65 to complete before doing a function 11 if the display did
not respond with the D1008065.
The double-row display control panel presents data like this:
xxxxxxxxxxxxxxxx
xxxxxxxxxxxxxxxx
Each word is 8 characters but 4 words are displayed at a time for words 12
through 19. For example, requesting word 12 will provide you:
word__12word__13
word__14word__15
Requesting word 13 will provide you:
word__16word__17
word__18word__19
The single-row display control panel presents data like this:
xxxxxxxx
Each word is 8 characters only and displayed individually. If you want word
17, you have to request function 17.
Important: In order to know where you are in the process the following
information is provided:
– Word 17 of the SRC D1008065 will contain the the number of function 65s
you have done. When it reaches a count of 7 the reset of the service tools
device ID password will take place. Word 18 will then be set to 00000000.
– Word 18 will show 00000001 until you have entered the seventh function
65. When the reset has completed, this word will be set to 00000000 unless
more than 5 minutes have elapsed.
Proceed to Reset the service tools device ID password on the PC.