Epson AcuLaser C2800 Service Manual page 369

A4 full color laser printer
Hide thumbs Also See for AcuLaser C2800:
Table of Contents

Advertisement

AcuLaser C2800/C2800D/C3800/C3800D
B
1)-1
1. Loosen the HARNESS ASSY C2 NO PAPER wrapped around the FEEDER ASSY UNIT OPT, and
pull the harness toward the SENSOR PHOTO:CST NO PAPER.
2. Remove the screw (silver, 6 mm) that secures the HOLDER NO SNR to the FEEDER ASSY UNIT
OPT, and remove the HOLDER NO SNR.
3. Release the three tabs that secure SENSOR PHOTO:CST NO PAPER to the HOLDER NO SNR,
and remove the SENSOR PHOTO:CST NO PAPER.
4. Disconnect the connector (P/J42121) of the SENSOR PHOTO:CST NO PAPER.
DISASSEMBLY/REASSEMBLY
SENSOR PHOTO:CST NO PAPER
2)
4) (J42121)
SENSOR PHOTO:CST NO PAPER
1)-2
Kmy03244EB
Disassembly/Reassembly
C
3)
2)
1)-1
1. While holding down the circular tab that secures the HOLDER NO PAPER L A4 to the SUPPORT
NUDGER ASSY, disengage the three tabs, and remove the HOLDER NO PAPER L A4 by sliding it
sideways.
The stopper of the ACTUATOR NO PAPER A4 should be placed underneath the
HOLDER NO PAPER L A4.
2. Pull out the shaft of the ACTUATOR NO PAPER A4 from the hole of the HOLDER NO PAPER R
A4, and remove the ACTUATOR NO PAPER A4.
ACTUATOR NO PAPER A4
ACTUATOR NO PAPER A4
1)-2
HOLDER NO
PAPER L A4
Tab
ACTUATOR
NO PAPER A4
Stopper
Kmy03245EA
Revision C
369