AcuLaser C2800/C2800D/C3800/C3800D
A B C D
1)
As the FUSER UNIT remains at hazardous temperature after turning the power off, be
careful not to burn yourself.
1. Release the lock on the right side of the FUSER UNIT.
2. Remove the three screws (silver, self-tapping, 10 mm) that secure the COVER SIDE R to the main unit.
3. Pull the COVER SIDE R so that it comes free from the two protrusions of the main unit.
4. Release the two tabs on the back side and the two tabs on the front side of the COVER SIDE R, and
remove the COVER SIDE R from the main unit.
DISASSEMBLY/REASSEMBLY
COVER SIDE R
COVER SIDE R
4)-1
4)-1
2)
3)
4)-1
3)
2)
4)-1
4)-2
2)
Kmy03005EA
Disassembly/Reassembly
A B C D
1)
1)
3)-1
1. Remove the four screws (silver, self-tapping, 10 mm) and the screw (silver, brimmed, self-tapping,
10 mm) that secure the COVER TOP to the main unit.
2. Pull the tabs of the COVER TOP outward so that it comes free from the two protrusion of the main unit.
3. Raise the COVER TOP to disengage the protrusion on the left side of the COVER TOP through the
hole in the main unit, and remove the COVER TOP.
Revision C
COVER TOP
1)
COVER TOP
1)
2)
2)
3)-2
Confidential
1)
285