Field Settings from Outdoor Unit
2.2

Setting Mode and Monitor Mode

The following 3 modes can be changed over with the button switches on the PCB and you can find the present
mode by the status of the H1P indicator.
(1) Setting mode 1 (H1P OFF)
Initial status (normal) : Also indicates during abnormal.
(2) Setting mode 2 (H1P ON)
Used to modify the operating status and to set program addresses, etc. Usually used in servicing the system.
(3) Monitor mode (H1P blinks)
Used to check the program made in setting mode 2.
Press the MODE (BS1) button for more
than 5 seconds.
Setting mode 2
Select a setting item with
the SET (BS2) button.
Press the RETURN (BS3) button.
Select a setting condition
with the SET (BS2) button.
Press the RETURN (BS3) button.
Setting condition
(Contents) display
Press the RETURN (BS3) button.
113
H1P H3P H5P H7P
H2P H4P H6P
MODE
SET
(BS2)
(BS1)
Setting mode 1
(Initial condition)
H1P
MODE
H1P
ON
MODE
Press the MODE (BS1) button.
RETURN
RESET
TEST
(BS3)
(BS4)
(BS5)
Press the MODE (BS1) button.
OFF
Monitor mode
Select a check item with
the SET (BS2) button.
Press the RETURN (BS3) button.
Contents display
Press the RETURN (BS3) button.
SiUS331708EA
H1P
Blinking
MODE
Press the MODE (BS1) button.