Compressor; Checking Procedures - Daikin Sensira Series Service Manual

Split r32
Table of Contents

Advertisement

2
|
Components

2.2 Compressor

2.2.1 Checking procedures

To perform an auditive check of the compressor
To perform a mechanical check of the compressor
Service manual
44
Is the problem solved?
No
INFORMATION
It is recommended to perform the checks in the listed order.
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Open the compressor insulation.
2 Turn ON the power using the respective circuit breaker.
3 Start the unit operation via the user interface.
4 Wait for - or create condition to operate the compressor.
5 Listen to the compressor when it tries to operate. Judge if a mechanical lock is
present.
INFORMATION
If you have a multimeter with data logging functionality, record the current in 1 of
the U‑V‑W wires at compressor start‑up. If mechanical lock is present, logged current
will drastically increase to a peak value and the unit will trigger an error.
INFORMATION
If a mechanical lock is present, also check and eliminate the root cause. Mechanical
lock is most likely caused by lack of lubrication (which might be related to overheat
or wet operation), failing crankcase heater (if available), impurities in the refrigerant,
....
A mechanical lock is present on the
compressor?
Yes
No
Prerequisite: First perform an auditive check of the compressor, see
"2.2.1 Checking
procedures" [
Prerequisite: Stop the unit operation via the user interface.
1 Turn OFF the respective circuit breaker.
Action
Return to the troubleshooting of the
specific error and continue with the
next procedure.
"2.10 Plate
Action
Replace the compressor, see
"2.2.2 Repair
Perform an mechanical check of the
compressor, see
procedures" [
4
 44].
FTXF20~71A + FTXF20~25B + FTXF20~42C + ATXF20~71A + ATXF20~42C
+ RXF20~71A + RXF20~60B + RXF20~42C + ARXF20~71A + ARXF20~42C
4
work" [
 101].
4
procedures" [
 49].
"2.2.1 Checking
4
 44].
Split Sensira R32
ESIE18-12E – 2021.02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents