Daikin Sensira Series Service Manual page 3

Split r32
Table of Contents

Advertisement

Version log
Version code
ESIE18-12
ESIE18-12B
The following updates have been applied to the Service Manual:
• Outdoor unit models RXF50B and RXF60B added.
• Indoor unit models ATXF25A and ATXF35A added.
• Technical data – Wiring diagram: Wiring diagrams for new models added.
• Technical data – Piping diagram: Piping diagrams for new models added.
Version code
ESIE18-12C
The following updates have been applied to the Service Manual:
• Outdoor unit models RXF20+25B added.
• Indoor unit models FTXF20+25B added.
• Inverter PCB – Checking procedures: To perform an electrical check of the inverter PCB updated.
• Outdoor unit fan motor: Checking procedures updated.
• Technical data – Wiring diagram: Wiring diagrams for new models added.
• Technical data – Piping diagram: Piping diagrams for new models added.
Version code
ESIE18-12D
The following updates have been applied to the Service Manual:
• Outdoor unit models ARXF20~71A added.
• Indoor unit models ATXF20A and ATXF50~71A added.
• Technical data – Wiring diagram: Wiring diagrams for new models added.
• Technical data – Piping diagram: Piping diagrams for new models added.
• Technical data – Piping diagram: Piping diagram for models RXF20+25B updated.
Version code
ESIE18-12E
The following updates have been applied to the Service Manual:
• Outdoor unit models RXF20~42C and ARXF20~42C added.
• Indoor unit models FTXF20~42C and ATXF20~42C added.
• Technical data – Wiring diagram: Wiring diagrams for new models added.
• Technical data – Piping diagram: Piping diagrams for new models added.
• High pressure switch – Checking procedures: To perform an electrical check of the high pressure switch updated
(operating + reset pressure values added).
• 4-way valve – Checking procedures: To perform an electrical check of the 4-way valve updated.
• Main PCB: Class 20~42 unit procedures updated.
• Main PCB: Class 50~71 unit procedures added.
• Outdoor unit fan motor – Checking procedures for Class 50~71units: To perform an electrical check of the
outdoor unit fan motor updated (resistance values updated)
• Indoor unit fan motor: Checking procedure updated.
• Reactors – Checking procedures: To perform an electrical check of the reactor updated.
• Reactors – Repair procedures: To remove and to install the reactor updated.
• Maintenance: To clean the indoor unit heat exchanger in extreme condition added.
FTXF20~71A + FTXF20~25B + FTXF20~42C + ATXF20~71A + ATXF20~42C
+ RXF20~71A + RXF20~60B + RXF20~42C + ARXF20~71A + ARXF20~42C
Split Sensira R32
ESIE18-12E – 2021.02
Description
Document release
See below
Description
See below
Description
See below
Description
See below
Date
October 2018
June 2019
Date
February 2020
Date
March 2020
Date
February 2021
Version log