Daikin Sensira Series Service Manual page 80

Split r32
Table of Contents

Advertisement

2
|
Components
Service manual
80
VDC
Com
DC–
U
DC–
V
DC–
W
Power module IPM2 for fan motor
1 Disconnect the fan motor connector from the main PCB.
2 Check the power module IPM2 in reference with the image and the table
below.
a U
b V
c W
d DC+
e DC–
INFORMATION
When measuring on the front of the main PCB, make sure to locally remove the
protective varnish with the test leads of the multi meter.
VDC
Com
U
DC+
V
DC+
W
DC+
DC–
U
DC–
V
DC–
W
Are the test results OK?
Yes
Ref
VDC
0.501 V
U
0.501 V
V
0.501 V
W
c
b
a
d
Ref
VDC
0.475 V
DC+
0.475 V
DC+
0.475 V
DC+
0.475 V
U
0.475 V
V
0.475 V
W
Action
Power modules are OK. Return to
"Checking
main PCB and continue with the next
procedure.
FTXF20~71A + FTXF20~25B + FTXF20~42C + ATXF20~71A + ATXF20~42C
+ RXF20~71A + RXF20~60B + RXF20~42C + ARXF20~71A + ARXF20~42C
Com
Ref
DC–
O.L
DC–
O.L
DC–
O.L
e
Com
Ref
U
O.L
V
O.L
W
O.L
DC–
O.L
DC–
O.L
DC–
O.L
4
procedures" [
 74] of the
Split Sensira R32