Daikin Sensira Series Service Manual page 59

Split r32
Table of Contents

Advertisement

About the installation of the expansion valve motor
FTXF20~71A + FTXF20~25B + FTXF20~42C + ATXF20~71A + ATXF20~42C
+ RXF20~71A + RXF20~60B + RXF20~42C + ARXF20~71A + ARXF20~42C
Split Sensira R32
ESIE18-12E – 2021.02
3 Wrap a wet rag around the expansion valve body and solder the expansion
valve pipes to the refrigerant pipes.
CAUTION
Overheating the valve will damage or destroy it.
4 After soldering is done, stop the nitrogen supply after the component has
cooled‑down.
a
b
a Putty
b Expansion valve pipe
c Expansion valve body
a Expansion valve pipe
b Expansion valve body
INFORMATION
The expansion valve and motor can have a different configuration / layout.
5 Reinstall the putty.
6 To install the expansion valve motor, see
7 Add
refrigerant
4
procedures" [
 133].
NOTICE
Select the correct type.
c
a
b
"2.3.2 Repair
to
the
refrigerant
2
Components
|
4
procedures" [
 56].
circuit,
see
"3.2.2  Repair
Service manual
59

Hide quick links:

Advertisement

Table of Contents
loading