a
a
f
d
a Tie strap
b Insulation
c Thermistor wire
d Clip
e Thermistor
f Thermistor holder
6 Cut all tie straps that fix the thermistor harness.
7 Disconnect the thermistor connector from the appropriate PCB and remove
the thermistor.
INFORMATION
Some of the thermistors are wired to the same connector. See connector and pin
information of the thermistors at the start of the electrical check procedure and
"5.2 Wiring
diagram" [
to the same connector.
8 When removing the complete set of thermistors wired to the same connector:
▪ Remove all other thermistors wired to the connector from their thermistor
holder,
▪ Disconnect the thermistor connector from the appropriate PCB,
▪ Remove the complete set of thermistors.
9 To install the thermistor, see
c
b
e
4
 142]. ALWAYS replace the complete set of thermistors wired
"Repair
procedures" [
FTXF20~71A + FTXF20~25B + FTXF20~42C + ATXF20~71A + ATXF20~42C
+ RXF20~71A + RXF20~60B + RXF20~42C + ARXF20~71A + ARXF20~42C
4
 121].