SENSOR
READI NGS
RI BBON SENSOR
LI MI TS
iPH REPORT
VI EW
PRI NT
I CON
DESCRI PTI ONS
M CL Opt ion s
The MCL Opt ions m enu cont ains MCL st art ing opt ions:
MCL at Power- UP
St art MCL
The m enu select ions are defined as follows:
D I SPLAYED I TEM
MCL AT POWER- UP
ENABLE
DI SABLE
START MCL
Ch a pt e r 4 – M e n u Syst e m
Displays t he values ( 0 – 255) from t he print er sensors, where:
THR
103
PS
003
THR = Pr int head t her m ist or sensor;
TRAN = Gap m edia sensor ( REFL when set t o reflect ive) ;
RI BM = Ribbon sensor;
24V = 24 volt power supply sensor ;
PS = Present sensor ;
HD = Pr int head posit ion sensor; and,
RANK = Pr int head ranking resist or.
Displays t he values from t he ribbon sensor readings ( see exam ple below) for
print ers equipped wit h t he t herm al t ransfer opt ion, where:
Displays t he I nt elliSEAQ™ print head report dat a, where:
Displays t he dat a.
Print s a reference label:
iPH REPORT
TUE 12: 44PM 23MAY2006
4212- HE25- 060224- 090
PRI NTHEAD SERI AL # : 5x- 00289
PRI NTHEAD MODEL # 163
PRI NTER SERI AL # 60430014
PRI NTHEAD I NCHES 11175
I NSTALLATI ON DATE - I NI TI AL 02/ 02/ 2006
I NSTALLATI ON DATE - LAST 28/ 02/ 2006
PRI NTHEAD CLEANI NG
CLEAN PROCEDURES: 0
CLEAN COUNTER RESET 0
NUMBER OF I NCHES - I NI TI AL 0
Displays t he various print er icon assignm ent s, list ed by group:
Syst em I cons
Net work I cons
I nput Type I cons
Opt ion I cons
Det erm ines if MCL should be st art ed at print er power- up.
St art s MCL at power- up of print er
Does not st art MCL
I m m ediat ely st art s MCL
TRAN
RI BM
091
009
HD
RANK
255
050
RI BBON ADC LOW
111
RI BBON ADC HI GH
249
I TEM D ESCRI PTI ON
24V
171
4 6