SENSOR
CALI BRATI ON
PERFORM
CALI BRATI ON
ADVANCED ENTRY
PAPER SENSOR
LEVEL
REFL PAPER
LEVEL
GAP SENSOR
LEVEL
MARK SENSOR
LEVEL
EMPTY SENSOR
LEVEL
TRAN SENSOR
GAI N
REFL SENSOR
GAI N
PRI NTHEAD
CLEANI NG
CLEAN HEAD
SCHEDULE
CLEAN HEAD
COUNTER
RESET COUNTER
CLEAN HEAD NOW
Ch a pt e r 4 – M e n u Syst e m
Select s t he m edia sensor calibrat ion m et hod, where:
Set s t he values via int ernal print er calculat ions, as described in t he STANDARD
CALI BRATI ON procedure.
Set s t he values via m anual ent ry ( t ypically for hard t o calibrat e label st ocks) , as
described in t he ADVANCED ENTRY CALI BRATI ON where:
Est ablishes t he t hreshold for t he paper value ( 0 - 255) , where 170 is t he default
set t ing.
Est ablishes t he t hreshold for t he reflect ive value ( 0 - 255) , where 170 is t he
default set t ing.
Est ablishes t he t hreshold for t he gap value ( 0 - 255) , where 040 is t he default
set t ing.
Est ablishes t he t hreshold for t he m ark value ( 0 - 255) , where 040 is t he default
set t ing.
Est ablishes t he t hreshold for t he em pt y value ( 0 - 255) , where 000 is t he default
set t ing.
Est ablishes t he sensit ivit y of t he t ransm issive sensor ( 0 - 31) , where 15 is t he
default set t ing.
Est ablishes t he sensit ivit y of t he reflect ive sensor ( 0 - 31) , where 15 is t he
default set t ing.
Cont rols t he aut om at ic cleaning alert and funct ion, where:
Specifies t he inch ( or cent im et er) count at which t o clean t he print head, and if
exceeded t hree t im es, declare a Head Cleaning Fault . ( Not e t hat t he specified
count [ 0 - 200 inches] will be m ult iplied by one t housand, and t hat zero [ t he
default set t ing] will disable t he funct ion.)
I ndicat es t he num ber of inches ( or cent im et ers) since a cleaning was last
init iat ed.
Reset s t he Clean Head Count er t o zero t o rest art t he Clean Head Schedule.
I nit iat es t he cleaning process and reset s t he Clean Head Count er.