Setting Area Boundaries - American Dynamics AD615 Operator's Manual

Deltadome programmable surveillance camera
Hide thumbs Also See for AD615:
Table of Contents

Advertisement

Figure 4-6: Program Area Boundaries Screen
The dome supports from 2 to 16 areas.

Setting Area Boundaries

Note
1. Select Alarms/Areas/Home from the Dome Configuration Menu.
2. Use the Tilt control to move the highlight bar to Programming Area Boundaries, then
press Focus Far.
The Program Area Boundaries screen appears:
3. Use the Pan control to position the camera at the starting point of the first area, then
press Zoom In or Zoom Out.
4. Use the Pan Right control to move the camera to the right until the ending point of the
area is seen. If you attempt to pan left, the error message in the note below appears.
5. Press Zoom In or Zoom Out to set the end point of the area.
The area number automatically advances.
4-10
PROGRAM AREA BOUNDARIES
PAN to start of BOUND
PAN RIGHT ONLY
ZOOM to mark BOUNDARY
FOCUS quits w/o changing
I M P O R T A N T
If areas are programmed, you cannot restore the old boundaries by selecting
Quit Without Saving from the Dome Configuration Menu. Be aware of
this limitation if you begin to make changes to the boundaries and change
your mind.
When areas are programmed, each area is assigned a default name.
Instructions for assigning new names appear in Chapter 5.
Displays the
1
number of the
area being set.
Message appears
when screen is
first displayed.
After first
boundary is set,
Focus saves and
exits.
Operator's Manual