American Dynamics ADC780 Installation And Setup Manual

Indoor/outdoor vandal-resistant cameras
Hide thumbs Also See for ADC780:

Advertisement

ADC780 Series Indoor/Outdoor
Vandal-Resistant Cameras
Installation and Setup Guide
Corner Mount
Surface Mount
The ADC780 series camera is for use in areas
subject to vandalism such as subway stations,
parking garages, prisons, police stations, corridors,
supermarkets, and elevators. This camera, which
comes in NTSC and PAL versions:
Is contained in a cast aluminum housing with a
polycarbonate window or dome. Three versions
are offered: corner, flush, or surface mount.
Has 480 lines of resolution to produce a sharp
picture with true color and has a 2.6–6mm
variable focal auto iris lens.
Is protected by tamper-resistant hardware.
Meets weather resistance standards:
− Surface Mount: NEMA 4, IP43
− Corner Mount: NEMA 3R, IP43
− Flush Mount: NEMA 1, IP40.

Outdoor Applications

Except when used in the flush mount, the camera
can be mounted outdoors using an optional heater
and thermostat that maintains the operating
temperature between –40°C to +50°C.
© 2005 Sensormatic Electronics Corp.
ADC780 SERIES VANDAL-RESISTANT CAMERA
INSTALLATION AND SETUP GUIDE
Flush Mount
1 of 11
Features
Adjustable camera mount
Indoor/Outdoor installation (except flush mount)
¾- and ½-inch conduit holes
24Vac hookup
2.6–6mm variable focal color camera with dc
auto-iris adjustment

Parts Supplied

Caution: Installation should be performed by
qualified service personnel and in accordance with
all local and federal electrical and building codes.
Housing and associated hardware
Mounting screws (4)
Anchors, plastic (4)
Screws, M6x35 (4)
Washers, metal (4)
O-rings, rubber (4)
Desiccant (for corner mount, surface mount)
Mounting Plate (for flush mount, surface mount)
Screws, M4 x 8 pan head (4) – flush and
surface mounts only (for connection to electrical
box mounting plate)
Parts not Supplied
Teflon
plumbers tape
®
UL-listed electrical tape
Silicone caulk
(for corner and surface mounts only)
Threaded conduit
IMPORTANT! Threaded rigid type conduit must
be used for the corner and surface mount
versions.

Tools Required

Torx wrench
Small Phillips screwdriver
Small slotted screwdriver
8000-2811-01, REV. C1

Advertisement

Table of Contents
loading

Summary of Contents for American Dynamics ADC780

  • Page 1: Parts Supplied

    Installation and Setup Guide Corner Mount Flush Mount Surface Mount The ADC780 series camera is for use in areas subject to vandalism such as subway stations, parking garages, prisons, police stations, corridors, supermarkets, and elevators. This camera, which comes in NTSC and PAL versions: Is contained in a cast aluminum housing with a •...
  • Page 2: Corner Mount Installation

    (A) and insert the washer and O- ring (B). Otherwise, just use the washer and O-ring (B). The O-ring goes on last. ADC780 SERIES VANDAL-RESISTANT CAMERA INSTALLATION AND SETUP GUIDE 3. Using the four mounting screws, attach the enclosure to the corner.
  • Page 3 Focus Adjustment Zoom Swivel camera holding yoke ADC780 SERIES VANDAL-RESISTANT CAMERA INSTALLATION AND SETUP GUIDE 7. Swivel the camera to adjust the ac phase control on the edge of the bottom board. 8. Select DIP switch settings (page 8). 9. Holding the yoke (not the camera lens barrel), swivel the camera to the desired view.
  • Page 4: Flush Mount Installation

    M4 Plastic Anchors (4x) FC1 M4 x 20 Flat Head Screws (4x) ADC780 SERIES VANDAL-RESISTANT CAMERA INSTALLATION AND SETUP GUIDE 3. Run 24vac and video cables through the opening in the ceiling. Then attach the enclosure to the gasket using screws shown.
  • Page 5: Surface Mount Installation

    Teflon Tape Screw Assembly (4x) ADC780 SERIES VANDAL-RESISTANT CAMERA INSTALLATION AND SETUP GUIDE 4. If connecting to an electrical box, see “Electrical Box Attachment”, page 5. If using the camera outdoors, see “Heater Installation”, page 7. If humidity is a factor, see “Heater/Fan”...
  • Page 6: Electrical Box Attachment

    13. Reattach the cover on the enclosure using the four Torx screws. 14. Place a bead of Silicone caulk everywhere where the surface mount meets the wall. ADC780 SERIES VANDAL-RESISTANT CAMERA INSTALLATION AND SETUP GUIDE Electrical Box Attachment Flush Mount 1.
  • Page 7: Heater Installation

    8. AC Terminal Block AC Camera Connection Thermostat PC Board ADC780 SERIES VANDAL-RESISTANT CAMERA INSTALLATION AND SETUP GUIDE Heater/Fan Installation (Surface Mount only) Remove the ac terminal block and wiring to the AC camera connection and replace it with the thermo- stat PC board and the heater/fan assembly.
  • Page 8: Dip Switch Default Settings

    8. Not Used (Don’t Care) AC/Heater Wiring Diagram (Corner Mount or Surface Mount only) Heater AC to Camera SW1 (Thermostat) ADC780 SERIES VANDAL-RESISTANT CAMERA INSTALLATION AND SETUP GUIDE AC/Heater/Fan Wiring Diagram (Surface Mount only) Note: • Red wire from the fan goes to the J3 terminal marked “+”.
  • Page 9 Dimensions Corner Mount 124.2mm 4.9" PT 3/4" 104.6mm 4.12" 86mm 3.39" ADC780 SERIES VANDAL-RESISTANT CAMERA INSTALLATION AND SETUP GUIDE Flush Mount 91.5mm 3.6" PT 1/2" 52.5mm 40.0mm 2.07" Surface Mount 91.5mm 3.60" 9 of 11 120.0mm 4.72" 1.57" 120.0mm 4.72"...
  • Page 10: Specifications

    (–4°F to +140°F) * North America: Listed Class 2 power supply required. European Union: Certified limited power source required. ADC780 SERIES VANDAL-RESISTANT CAMERA INSTALLATION AND SETUP GUIDE Mechanical Dimensions ... (see page 9) Weight ... Flush Mount: 450g (1 lbs) Surface Mount: 590g (1.3 lbs)
  • Page 11: Regulatory Compliance

    DFARS 252.227.7013. Unpublished - rights reserved under the Copyright Laws of the United States. TRADEMARK NOTICE: American Dynamics, and the American Dynamics logo are registered trademarks of Sensormatic Electronics Corporation. Other product names (if any) mentioned herein may be trademarks or registered trademarks of Sensormatic or other companies.