Pump Screens - Graco HydroShield Instructions Manual

Air-assisted batch waterborne isolation systems
Table of Contents

Advertisement

Setup Menus

Pump Screens

Screens
Pump
Pump
Screens
Use the Pump screens to enter volume information
about the isolation fluid pump and to manually purge
the system in the event of a problem.
Pump
Pump Screen
Pump
Screen 1: 1: 1: Pump
Screen
Pump Volume
Pump
Use this screen to enter global settings for volume
information about the isolation fluid pump and
how the light tower indicates material levels in the
pump. To configure different pump settings for
specific paint colors, set those as part of a Preset.
See
Presets, page
56.
Pump
Pump
Pump Volume:
Volume: The total volume capacity of the
Volume:
pump in cubic centimeters.
Max
Max Fill:
Max
Fill: The pump will not fill past this volume, as
Fill:
set by the user.
Start
Start
Start Fill:
Fill: The system will not begin to fill until the
Fill:
pump volume drops below this volume, as set by
the user. Setting this appropriately may help avoid
delays and unnecessary refills.
Green On:
On: The light tower turns green when the
Green
Green
On:
pump volume is above the Green On setting. The
light tower turns yellow when it is between the Green
On and Red On settings.
Red On:
On: The light tower turns red when the pump
Red
Red
On:
volume is below the Red On setting.
58
Volume
Volume
Pump Screen
Screen 2: 2: 2: Override
Override Purge
Pump
Pump
Screen
Override
Use this screen in troubleshooting situations to empty
the isolation fluid pump and manually purge the
system. This screen allows operators to override the
isolation valve sensors (103) that detect the shuttle
position, as well as the linear sensors (321) on the
isolation fluid pump that detect the full and empty
pump status.
Open the cabinet and then follow the sequence on
this screen to manually empty and refill the pump.
Open the cabinet and then follow the sequence on
this screen to manually empty and refill the pump.
1: 1: 1: Shuttle:
Shuttle: Press to enter Standby mode. Press
Shuttle:
again to drive the shuttle down.
2: 2: 2: Shuttle
Shuttle Down:
Down: Check inside the cabinet to make
Shuttle
Down:
sure that the shuttle is down. Press Shuttle Down to
confirm that the shuttle is in the down position.
3: 3: 3: Empty:
Empty: Press and then trigger the gun to empty
Empty:
the pump of fluid.
4: 4: 4: Fill:
Fill: Press to fill the pump. To clean the pump,
Fill:
make sure that a hose supplying cleaning fluid is
connected.
If desired, press Empty and Fill again until clean fluid
comes out of the gun.
Now that the system is purged, continue
troubleshooting the issue.
Purge
Purge
3A7370C

Advertisement

Table of Contents
loading