Page 1
This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. INSTRUCTIONS Husky Air Spray/HVLP Systems STAINLESS STEEL FLUID FITTINGS, PTFE PTFE PTFE ACETAL PUMP WITH 0.7 MPa, 7 bar (100 psi) Maximum Fluid Working Pressure 0.7 MPa, 7 bar (100 psi) Maximum Air Input Pressure Model 236–870, Series A Pail Mount Unit with Fluid Regulator Model 224–833, Series B...
WARNING WARNING TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed. Know the specific hazards of the fluid you are using. Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.
Assembling Pail Mount Units 1. Insert the suction tube (27) into the elbow (15) to its full depth. Tighten the nut securely. See Fig. 1. 2. Insert the recirculation tube (28) into the connector (16) to its full depth. Tighten the nut securely. Model 236–412 Fig.
Page 5
Assembling the Wall Mount Unit Install the wall bracket (2) 5 ft (1.52 m) above the floor. Use the mounting hole layout shown on page 18. Be sure the wall is strong enough to support the weight of the pump and hoses, any accessories, the fluid, and stress caused by pump operation.
General Information 1. The Typical Installations shown on pages 7 and 8 are only a guide for selecting and installing sys- tem components. Contact your Graco distributor or Graco Technical Assistance (see back page) for assistance in planning a system to suit your needs. 2.
Page 7
HVLP T ypical Installation – Pail Mount Models with Fluid Regulator Husky 307 Pump Bleed-Type Master Air Valve (required for pump) Air Supply Line Air Line Quick Disconnect Master Air Valve (for accessories) Air Line Filter G Gun Air Regulator Pump Air Regulator Fluid Drain Valve (required) Fluid Recirculation Line...
Page 8
NOTE: Some components shown are included with the sprayer, depending on the model. Refer to the parts lists on pages 12–17 for parts included in your sprayer. Fig. 4 Installation Air Spray T ypical Installation – Wall Mount Models with Surge Tank G Gun Air Regulator M Surge Tank and Filter Husky 307 Pump...
Page 9
Grounding WARNING FIRE AND EXPLOSION HAZARD This pump must be grounded. Before operating the pump, ground the system as explained below. Also read the sec- tion FIRE OR EXPLOSION HAZARD on page 3. To reduce the risk of static sparking, ground the pump and all other equipment used or located in the pumping area.
Pressure Relief Procedure WARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci- dentally. To reduce the risk of an injury from acci- dental spray from the gun, splashing fluid, or mov- ing parts, follow the Pressure Relief Procedure whenever you: are instructed to relieve the pressure,...
Pump Shutdown WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 10. At the end of the work shift, relieve the pressure. Flushing and Storage WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 10.
Page 12
Model 236–412, Series A Includes items 1–42 Part Description D31–331 PUMP, Husky 307; SST/ See 308–553 for parts 235–505 COVER, pail; stainless steel 111–276 THUMBSCREW; 5/16–18 unc; 1” (25.4 mm) long; sst 104–119 SCREW, cap, hex hd; 1/4–20 unc–2a; 0.875” (22 mm) long; sst 104–123 LOCKWASHER;...
Page 13
Model 236–412, Series A Includes items 1–42 Torque to 35–55 in–lb (4.0–6.2 N.m). Do not over-torque. Insert tube into connector (16) to full depth and tighten nut securely with wrench. Insert tube into elbow (14) to full depth and tighten nut securely with wrench. Insert tube into elbow (15) to full depth and tighten nut securely with wrench.
Page 14
Model 236–870, Series A Includes items 1–35 and 42 Model 224–833, Series B Includes items 1–42 Part Description D31–331 PUMP, Husky 307; SST/ See 308–553 for parts 235–505 COVER, pail; stainless steel 111–276 THUMBSCREW; 5/16–18 unc; 1” (25.4 mm) long; sst 104–119 SCREW, cap, hex hd;...
Page 15
Model 236–870, Series A Includes items 1–35 and 42 Model 224–833, Series B Includes items 1–42 Torque to 35–55 in–lb (4.0–6.2 N.m). Do not over-torque. Insert tube into connector (16) to full depth and tighten nut securely with wrench. Insert tube into elbow (14) to full depth and tighten nut securely with wrench.
Page 16
Model 236–628, Series A Includes items 1–26 and 34–42 Model 236–868, Series A Includes items 1–26, 34–37, and 42 Model 236–869, Series A Includes items 1–37 and 42 Model 236–414, Series A Includes items 1–42 Part Description D31–331 PUMP, Husky 307; SST/ See 308–553 for parts 224–835 WALL BRACKET KIT...
Page 17
Model 236–628, Series A Includes items 1–26 and 34–42 Model 236–868, Series A Includes items 1–26, 34–37, and 42 Model 236–869, Series A Includes items 1–37 and 42 Model 236–414, Series A Includes items 1–42 Torque to 35–55 in–lb (4.0–6.2 N.m). Do not over-torque. Insert tube into connector (28) to full depth and tighten nut securely with wrench.
Model 236–412 13.1 in. (332.7 mm) Pail is not included. Maximum pail outer diameter is 12.125 in. (308 mm). Wall Mounting Hole Layout 9.0 in. (228.6 mm) (WALL VIEW 5 in. (127 mm) MOUNTING BRACKET) 6.74 in. (171.2 mm) Four 0.438 in. (11 mm) Dia. Holes (To Mount Bracket To Wall) Dimensions Models 236–870 and 224–833...
The Graco Warranty and Disclaimers Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special extended or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.