Download Print this page
Graco Hydra-Spray B Series Instructions Manual
Graco Hydra-Spray B Series Instructions Manual

Graco Hydra-Spray B Series Instructions Manual

23:1 ratio monark
Hide thumbs Also See for Hydra-Spray B Series:

Advertisement

Quick Links

Instructions – Parts List
Parts
5 GALLON (19 LITER) PAIL-MOUNTED
23:1 Ratio Monarkr
Hydra-Sprayr Sprayers
2760 psi (19 MPa, 190 bar) Maximum Fluid Working Pressure
120 psi (0.8 MPa, 8 bar) Maximum Air Inlet Pressure
Part No. 226970, Series B
With Agitator
Part No. 231114, Series A
Without Agitator
Read warnings and instructions.
See page 2 for table of contents.
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 1983, Graco Inc. is registered to I.S. EN ISO 9001
Model 226970 Shown
II 1/2 G T6
0359
ITS03ATEX11251
307621R
05983

Advertisement

loading

Summary of Contents for Graco Hydra-Spray B Series

  • Page 1 Model 226970 Shown 05983 Read warnings and instructions. See page 2 for table of contents. II 1/2 G T6 0359 ITS03ATEX11251 GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 Copyright 1983, Graco Inc. is registered to I.S. EN ISO 9001...
  • Page 2 D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before operating the equipment. D Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. D Do not alter or modify this equipment.
  • Page 3 WARNING INJECTION HAZARD Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury. D Fluid injected into the skin might look like just a cut, but it is a serious injury.
  • Page 4 WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. D Ground the equipment and the object being sprayed. Refer to Grounding on page 5. D If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing immediately.
  • Page 5 FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below. Also read NOTE: Always use Genuine Graco Parts and Acces- the section FIRE AND EXPLOSION sories, available from your Graco distributor. If you HAZARD on page 4.
  • Page 6 Setup Supplied Components Available Accessories (must be purchased separately) Refer to Fig. 2. Refer to Fig. 2. Use necessary adapters when instal- WARNING ling these accessories. A red-handled bleed-type master air valve (1) and D The air filter (D) removes harmful dirt and moisture a fluid drain valve (20) are supplied.
  • Page 7 Setup COMPONENTS YOU MUST SUPPLY SUPPLIED WITH ALL MODELS SUPPLIED WITH MODEL 226970 ONLY Red-Handled Bleed-Type Master Electrically Conductive Air Supply Hose 58 Gun Swivel Air Valve (required, for pump) Bleed-Type Master Air Valve 59a Agitator Air Line Bushing (for accessories) 59b Agitator Air Hose Drain Valve Elbow Air Line Moisture Trap and Drain Valve...
  • Page 8 Operation Pressure Relief Procedure Packing Nut/Wet-Cup WARNING WARNING INJECTION HAZARD The system pressure must be manually To reduce the risk of serious injury whenever you relieved to prevent the system from are instructed to relieve pressure, always follow the starting or spraying accidentally. Fluid Pressure Relief Procedure at left.
  • Page 9 Operation Prime the Pump Set the Air and Fluid Pressure WARNING 1. See Fig. 3. Remove the tip guard and spray tip (31) from the gun (9). See the gun instruction To reduce the risk of serious injury whenever you manual.
  • Page 10 Operation Shutdown and Care of the Pump CAUTION WARNING Never leave water or water-base fluid in the pump overnight. If you are pumping water-base fluid, flush To reduce the risk of serious injury whenever you with water first, then with a rust inhibitor such as are instructed to relieve pressure, always follow the mineral spirits.
  • Page 11 Operation Red-Handled Bleed-Type Master Pump 27 Air Manifold Air Valve (required, for pump) Airless Spray Gun 57 Ground Wire (required; see page 5 Drain Valve Elbow 10 Fluid Filter for installation instructions) Air Regulator 20 Fluid Drain Valve (required) 59a Agitator Fluid Supply Hose 21 19 Liter (5 Gallon) Pail 59b Agitator Air Hose...
  • Page 12 Parts Part No. 231114, Series A (includes items 1–57) Part of the pump (7). 51 (Ref) 05982 307621...
  • Page 13 Parts Part No. 231114, Series A (includes items 1–57) Ref. Ref. Part No. Description Qty. Part No. Description Qty. 113333 BLEED VALVE, red-handled; 101962 SCREW, socket hd set; 1/4–20 x 3/8 npt (m x f) 3/8” (10 mm) long 100081 BUSHING;...
  • Page 14 Parts Part No. 226970, Series B (includes items 1–59) Part of the pump (7). The agitator (59) includes items 59a and 59b. 51 (Ref) 05981 307621...
  • Page 15 Parts Part No. 226970, Series B (includes items 1–59) Ref. Ref. Part No. Description Qty. Part No. Description Qty. 113333 BLEED VALVE, red-handled; 151519 NIPPLE, reducing; 1/4 x 1/8 npt 3/8 npt (m x f) 162376 MANIFOLD, air; 1/2 npt (m x f); 100081 BUSHING;...
  • Page 16 Technical Data Category Data Maximum fluid working pressure 2760 psi (19 MPa, 190 bar) Maximum air input pressure 120 psi (0.8 MPa, 8 bar) Ratio 23:1 Pump performance data See pump manual 307619 Air consumption data See pump manual 307619 Air inlet size 1/2 npt(f) at inlet fitting;...
  • Page 17 Dimensions Model 226970 Shown 05983 Pump Model Weight 231114 29 in. (737 mm) 13 in. (330 mm) 48 lb (22 kg) 226970 29 in. (737 mm) 13 in. (330 mm) 50 lb (23 kg) 307621...
  • Page 18 With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.

This manual is also suitable for:

Hydra-spray a series226970231114