Siemens SINAMICS S120 Manual page 225

Cabinet modules liquid cooled
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Article No.
Dimensions (standard version)
- width
- height
- depth
Weight, approx. (standard version)
Depending on the ambient temperature and humidity, see Chapter "Protection against condensation" in Section "Com-
1)
missioning the cooling circuit".
This value applies to the water coolant option; for other coolant types, see Chapter "Cooling circuit and coolant proper-
2)
ties".
0 °C with antifreeze.
3)
The specified power loss represents the maximum value at 100 % utilization. The value in normal operation is lower.
4)
With option W01, the cabinet width increases to 1000 mm.
5)
With option W01, the cabinet weight increases by approximately 110 kg.
6)
For Heat Exchanger Modules for line voltages of 3 AC 500 ... 690 V, the voltage is adapted to the 3 AC 400 V / 50 Hz or
7)
460 V / 60 Hz supply voltage using a transformer.
Cabinet Modules liquid cooled
Equipment Manual, 04/2020, A5E37067587A
6SL3705-
0RG23-
2AA5
7)
mm
600
5)
mm
2200
mm
600
kg
350
6)
Cabinet Modules
6.4 Heat Exchanger Modules
0RG24-
0RG27-
8AA5
2AA5
7)
7)
600
600
5)
5)
2200
2200
600
600
350
360
6)
6)
0RG31-
1AA5
7)
600
5)
2200
600
360
6)
223