3Com Switch 8800 Configuration Guide
Chapter 2 Logging into Switch
Note:
By default, the password is required for authenticating the Modem user to log in the
switch. If a user logs in via the Modem without password, he will see the prompt "Login
password has not been set !.".
<SW8800> system-view
System View: return to User View with Ctrl+Z..
[SW8800] user-interface aux 0
[SW8800-ui-aux0] set authentication password simple xxxx (xxxx is the preset login
password of the Modem user.)
Step 2: As shown in the figure below, to set up the remote configuration environment,
connect the Modems to a PC (or a terminal) serial port and the switch AUX port
respectively.
Modem serial port line
Modem
Telephone line
PSTN
Modem
AUX port
Remote tel:
82882285
Figure 2-8 Set up remote configuration environment
Step 3: Dial for connection to the switch, using the terminal emulator and Modem on the
remote end. The number dialed shall be the telephone number of the Modem
connected to the switch. See the two figures below.