Hour Meter - Toro Groundsmaster 7200 Service Manual

Zero turn rotary mower with kubota engine
Hide thumbs Also See for Groundsmaster 7200:
Table of Contents

Advertisement

Hour Meter

1. Make sure ignition switch is in the OFF position. Lo-
cate the hour meter and disconnect the wire harness
electrical connector from the meter.
2. Connect the positive (+) terminal of a 12 VDC source
to the positive terminal of the hour meter.
3. Connect the negative (- ) terminal of the voltage
source to the other terminal of the hour meter.
4. The hour meter should move 1/10 of an hour in six
minutes.
5. Disconnect the voltage source from the hour meter.
6. Replace the hour meter if necessary.
Figure 9
7. Connect harness electrical connector to the hour
meter.
Electrical System