Removal (Fig. 3)
NOTE: See Operator's Manual for air cleaner mainte-
nance procedures and intervals.
1. Park machine on a level surface, lower cutting unit
(or implement), stop engine, engage parking brake and
remove key from the ignition switch.
2. Unlatch and raise hood.
3. Remove air cleaner components as needed using
Figures 3 and 4 as guides.
4. Check air cleaner housing and cover for damage that
could cause possible air leaks.
5. Check air inlet hoses for damage or wear.
Installation (Fig. 3)
IMPORTANT: Any leaks in the air filter system will
allow dirt into engine and will cause serious engine
damage. Make sure that all air cleaner components
are in good condition and are properly secured dur-
ing assembly.
1. Assemble air cleaner system using Figures 3 and 4
as guides.
A. Make sure that vacuator valve is pointed down af-
ter assembly (Fig. 4).
B. Make sure that inlet hose (item 2) has clearance
around it at all points after air cleaner installation is
completed.
C. If indicator and nipple were removed from hous-
ing, apply sealant to threads of nipple before assem-
bly.
2. Close and latch hood.
Groundsmaster 7200/7210
2
1
8
1. Indicator
2. Housing
3. Cover
4. Vacuator valve
Page 3 – 7
3
5
4
6
7
Figure 4
5. Air filter
6. Gasket
7. Bracket
8. Nipple
Kubota Diesel Engine