JRR200 Route Reflector Hardware Guide
JRR200 Route Reflector AC Power Supply Specifications
24
Table 9: AC Power Supply Unit LEDs
LED
Color
AC
Unlit
Green
DC
Unlit
Green
! (Fault)
Amber
Unlit
NOTE:
If both the AC LED and the DC LED are unlit, either the AC power cord is
not installed properly or the power supply unit fuse has failed.
If the AC LED is lit and the DC LED is unlit, the AC power supply unit is
installed properly, but the power supply unit has an internal failure.
Table 10 on page 24
lists the specifications for an AC power supply.
Table 10: AC Power Supply Specifications
Item
AC input voltage
AC input line frequency
AC input current rating
AC output power
State
Description
Off
Indicates one of the following:
Power input voltage is not within the normal
operating range.
No power input.
Steady
Input power present and is within the normal
operating range.
Off
No DC power output or abnormal DC output.
On steadily
DC power output is within the normal operating
range.
On steadily
Power supply unit failure.
Blinking
Invalid power supply unit.
Off
Power supply unit is functioning normally.
Specification
Operating range:
Low-voltage line—100–127 VAC
High-voltage line—200–240 VAC
50–60 Hz
Low-voltage line—4 A
High-voltage line—2 A
Low-voltage line—650 W
High-voltage line—650 W
Copyright © 2018, Juniper Networks, Inc.