3.
Check the distance between the upper tube of
the door frame and the lower lip of the molded
hood
(Figure
55).
Note:
The distance should be between 3.2 mm
(1/8 inch) and 9.6 mm (3/8 inch).
Figure 55
1. Lower lip of the molded
hood
2. The measurement is
between an 3.2 mm (1/8
inch) and 9.6 mm (3/8
inch).
4.
If adjustment is needed, adjust the hinge stops
on both sides so that the distance between the
upper tube of the door frame and the lower lip
of the molded hood is between an 3.2 mm (1/8
inch) and 9.6 mm (3/8 inch).
Note:
Make sure that both the left and right
hinge stops are adjusted the same distance.
5.
Tighten the nuts and install the side plates.
g007379
3. Upper tube of the door
frame
1. Hinge stop
38
Figure 56
2. Nut