Sysmac Error Status Codes; A-4-1 Error List - Omron 1 S Series User Manual

With built-in ethercat communications and safety functionality
Hide thumbs Also See for 1 S Series:
Table of Contents

Advertisement

Appendices
A-4 Sysmac Error Status Codes
This section lists and describes the error event codes that you can see in Sysmac Studio.
A-4-1
Error List
The errors (events) that can occur in 1S-series Servo Drives Advance Type with Built-in EtherCAT
Communications are given on the following pages.
Event levels are given in the table as follows:
Min: Minor fault level
Obs: Observation
Info: Information
Refer to the NJ/NX-series Troubleshooting Manual (Cat. No. W503) for all of the event codes that may
occur in an NJ/NX-series Controller.
Event code
Event name
(hex)
04B50000
Inrush Current Pre-
vention Circuit Error
04B60000
Regeneration Cir-
cuit Error
05430000
ESC Error
08390000
Power Module Error
083B0000
Self-diagnosis Error
A - 116
Description
An error of inrush current
prevention circuit was
detected.
An regeneration circuit error
was detected.
An error occurred in the
EtherCAT slave communi-
cations controller.
An error was detected in the
power module.
An error was detected by
the self-diagnosis of the
safety function.
1S-series with Built-in EtherCAT Communications and Safety Functionality User's Manual (I621)
Assumed cause
• Inrush current prevention
circuit failure
• There is a short circuit
between B2 and N2/N3.
• Regeneration circuit failure
• Noise into wiring of the
external regeneration resis-
tor.
• Error of the EtherCAT slave
communications controller
or false detection when the
AL status code is 0051 hex
• Error access from the
non-OMRON EtherCAT
master when the AL status
code is 0050 hex
• There is a short-circuit,
ground fault, or contact fail-
ure on the U, V, or W motor
cable
• There is a short-circuit on
the wiring of External
Regeneration Resistor or
the resistance value is small
• The insulation resistance
failed between the U, V, or
W motor cable and the
motor ground wire
• Servo Drive failure
• False detection due to a
data read error that was
caused by excessive noise
• Hardware failure
Level
Refer-
ence
P. A-133
P. A-133
P. A-134
P. A-135
P. A-136

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R88m-1am seriesR88m-1al seriesR88d-1san-ect seriesR88d-1san02h-ectR88d-1san04h-ectR88d-1san08h-ect ... Show all

Table of Contents