Pentax DSI-200 Series User Manual page 84

Advertisement

P4-00
P4-01
P4-02
As shown in the figure above, the control mode is in the SB1 button closed state, press the
SB2 button inverter running, K disconnect the inverter forward, K closed inverter reverse;
SB1 button off instantaneous inverter shutdown. During normal startup and operation, the
SB1 button must be closed and the command of the SB2 button will take effect at the
closing action edge.
Terminal UP/DOWN Frequency
P4-12
Set range
For setting the terminal UP / DOWN to adjust the set frequency, the speed of the frequency
change, that is, the amount of change per second.
AI curve 1 min input
P4-13
Set range
AI Curve 1 minimum input
corresponds to setting
P4-14
Set range
AI Curve 1 maximum input
P4-15
Set range
AI Curve 1 maximum input
corresponds to setting
P4-16
Set range
AI1 Input filter time
P4-17
Set range
S1
Terminal
function
choose
S2
Terminal
function
choose
S3
Terminal
function
choose
Figure 6-11 Three - wire control mode 2
change rate
1
Forward and reverse
2
direction of operation.
Three - wire operation
3
control
Factory default
0.01Hz/s~65.535Hz/s
Factory
default
0.00V~P4-15
Factory
default
-100.00%~100.0%
Factory
default
P4-13~10.00V
Factory
default
-100.00%~100.0%
Factory
default
0.00s~10.00s
- 84 -
RUNNING
1.00Hz/s
0.00V
0.0%
10.00V
100.0%
0.10s