Pentax DSI-200 Series User Manual page 65

Advertisement

Group four:P8-07、P8-08;
Combined frequency of
auxiliary frequency source
P0-21
Set range
This function code is valid only when the frequency source is selected as the master and
slave operation.
When the frequency source is the main auxiliary operation, P0-21 is used as the bias
frequency, and the result of the main and auxiliary operation is superimposed as the final
frequency setting value, so that the frequency setting can be more flexible.
Frequency command
resolution
P0-22
Set range
This parameter is used to determine the resolution of all frequency dependent function codes.
Digital setting frequency stop
memory selection
P0-23
Set range
This function is valid only when the frequency source is digital.
"No memory" means that the digital setting frequency value is restored to the value of P0-
08 (preset frequency) after the inverter is stopped, and the frequency correction of the
keyboard ▲, ▼ key or terminal UP and DOWN is cleared.
"Memory" means that the digital setting frequency is set to the set frequency of the last stop
time when the inverter is stopped, and the frequency correction of the keypad ▲, ▼ key or
terminal UP and DOWN remains valid.
Acceleration /
deceleration time
reference frequency
P0-25
Set range
Acceleration/deceleration time, is from zero to P0-25 set the frequency between the
acceleration and deceleration time, Figure6-3 for the acceleration and deceleration time
diagram.
When P0-25 = 1, the acceleration / deceleration time is related to the set frequency. If the
frequency is changed frequently, the acceleration of the motor is changed, and the application
needs attention.
Run time frequency command UP
P0-26
/ DOWN reference
Factory default
0.00Hz~max frequency P0-10
Factory default
1:0.1Hz
Factory default
0:non-memory
Factory default
0 : max frequency ( P0-10 )
2:100Hz
Factory fault
- 65 -
0.00Hz
2
2:0.01Hz
1
1:memory
0
1 : set frequency
0