Purge Air and Flush Fluid From
Lines
To avoid fire and explosion:
Flush equipment only in a well-ventilated area.
Ensure main power is off and heater is cool before
flushing.
Do not turn on heater until fluid lines are clear of
solvent.
1. Remove both recirculation tubes (P) from the tanks
and secure each one in a dedicated waste
container.
2. Set function knob to Stop/Park
STATUS
2
1
0
+
-
3. Plug in power cords(s). See Table 2, page 16.
4. Open both pump fluid inlet valves (V, shown in open
position).
V
332144H
P
ti21488A
.
3
4
5
6
7
8
9
10
ti21490a
ti21917a
5. Turn on Motor Power. System status indicator (AY)
should turn on.
6. Set Recirc/Spray valves to Recirc.
7. Set function knob to Slow Recirc
.
-
STATUS
2
3
1
4
0
5
6
+
7
8
-
9
10
8. When clean fluids exit both recirculation tubes (P),
set function knob to Stop/Park
0
+
-
9. Replace the recirculation tubes (P) in the supply
tanks.
or Fast Recirc
-
STATUS
2
3
1
4
0
5
6
+
7
OR
8
-
9
10
.
2
3
1
4
5
6
7
8
9
10
ti21490a
Setup
ti21495a
ti21489a
19