Repair; Air Cartridge Replacement Procedure; Trigger Procedure - Graco PerformAA 15 Instructions - Parts Manual

Table of Contents

Advertisement

Repair

Repair
To avoid injury, follow Pressure Relief Procedure,
page 15, before checking or repairing the gun.
Check all possible remedies in the troubleshooting
charts before disassembling the gun. See
Troubleshooting, page 25.
Air Cartridge Replacement
Procedure
Use an air cartridge replacement kit to replace the air
cartridge assembly (21) and the u-cup (2). See Fluid
Cartridge Repair Kits, page 55.
1. Follow the Pressure Relief Procedure, page 15.
2. Loosen the air cartridge assembly (21) from back of
gun body with the gun tool (29).
F
. 42: Air cartridge installation
IG
3. Slide assembly (21) out of the gun.
4. Follow the U-Cup Replacement Procedure,
page 31 if needed.
30
21
1
Torque to 175-185
in-lb (20-21 N•m)
Lubricate lightly.
3
5. Lubricate the air cartridge tip and thread the air
cartridge assembly (21) into the back of the gun.
Torque to 175-185 in-lb (20-21 N•m). See F

Trigger Procedure

Follow this procedure to remove and install the trigger
assembly or to replace the trigger assembly with kit
26B721.
Remove the Trigger
1. Follow the Pressure Relief Procedure, page 15.
2. Use the nut driver (25) to loosen the trigger nut (11).
3. Remove the trigger pin (10) from the gun to release
the trigger (9).
Install the Trigger
1. Position the trigger (9) between the needle washer
and the needle housing (6b).
1
Torque to 20-30 in-lb
2 4 5 6 7
(2-3 N•m)
1
11
2 4 5 6 7
9
F
. 43: Trigger placement
IG
2. Insert the trigger pin (11).
3. Thread the trigger nut (10). Torque the trigger pin
(11) and trigger nut (10) to 20-30 in-lb (2-3 N•m).
. 42.
IG
6b
washer
1
10
2 4 5 6 7
3A8099A

Advertisement

Table of Contents
loading