This is the display screen that appears during an
active deviation. A and B pressure are shown. Refer
to the following table for more information.
Icon
Icon
Icon
System Status
System
System
Indicates that there is an active
deviation.
26
Status
Status
Information Screen
Screen
Information
Information
Screen
The information screen is displayed when an alarm
is active. It shows the active alarm code and the A
and B pressure conditions at the time of the alarm, if
applicable.
To toggle between the Alarm Active screen and the
Alarm Information screen, press:
The red LED will flash when an alarm is present.
Refer to the following table for more information.
Icon
Icon
Icon
System Status
System
System
Indicates that there is an active
alarm. The red light on the front
LED will be flashing and the system
is disabled.
Active Alarm Code
(see
Error Codes, page
NOTE: To clear the alarm, see
NOTE:
NOTE:
Manual
Manual Bypass
Manual
Bypass
Bypass Mode
Mode
Mode
If the user needs to spray with one of the above errors
active, set the Lower Spray Pressure Limit equal
to the High Pressure Alarm Limit to enter Manual
Bypass Mode. Only use Manual Bypass Mode for
emergency operation. The XP PressureTrak no
longer monitors the pressures and will not shut off
the sprayer.