6.
Install Fluid Temperature
Sensor (FTS)
The Fluid Temperature Sensor (FTS) is supplied.
Install FTS between main hose and whip hose.
CAUTION
To prevent damage to probe, do not kink or exces-
sively bend whip hose. Do not coil hose tighter than
the minimum bend radius of 3 ft (0.9 m). Do not sub-
ject hose to excessive weight, impact, or other abuse.
a.
Carefully extend FTS probe (S). Do not
bend or kink probe. Insert in component
A (ISO) side of main hose (B).
b.
Connect FTS (C) to whip hose (D).
Y
Z
F

. 6. Install Fluid Temperature Sensor (FTS)

IG
309551C
V
B
c.
Connect whip hose ground wire (U) to
ground screw on underside of FTS.
d.
Connect main hose (B) to FTS (C).
e.
Connect electrical connectors (V).
Secure connections with plastic ties
(W).
f.
Connect air hose (F) to whip air hose
(X).
g.
Connect main hose cable (Y) to FTS.
Slide insulator sleeves over connection.
Leave slack (Z) in cables as stress
relief, to prevent cable failure.
V
U
C
S
F
W
D
X
TI2684a1