The Fluid Temperature Sensor (FTS) is supplied with
the system. Install FTS between main hose and whip
hose. See your heated hose manual for instructions.
Figure 15
Test/Removal
Test/Removal
Test/Removal
1. Perform
Shutdown, page
2. Remove tape and protective covering from FTS.
Disconnect hose cable (F).
3. If FTS is not reading properly at the end of the
hose, see
Check RTD Cables and FTS, page
333024S
Sensor (FTS)

(FTS)

Sensor
(FTS)
46.
69.
4. If FTS fails, replace FTS.
a. Disconnect air hoses (C,L) and electrical
connectors (D).
b. Disconnect FTS from whip hose (W) and
fluid hoses (A, B).
c. Remove ground wire (K) from ground screw
on underside of FTS.
d. Remove FTS probe (H) from component A
(ISO) side of hose.
Repair