1 x PUK (incl. flush-mount box)
TM
1 x win:clip
key
1 x screwdriver with round handle
connection terminal with 5 poles
name plate, empty and with light symbol
hexagon socket screws
product information
programming table
General safety regulations
Attention! Mounting, installation, commissioning and repair of electronic devices have
!
to be carried out only by qualified electricians. Thus, the standards and instructions for
the installation of systems have to be observed.
For working on systems with main connection of 230 V alternating voltage, the safety re-
quirements according to DIN VDE 0100 must be observed.
When installating TCS:BUS systems, the general safety regulations for telecommunication
systems according to VDE 0800 must be observed. Inter alia:
separated conduit of heavy current and low current lines,
minimum distance of 10 cm in case of a common conduit,
use of separators between heavy and low current lines within shared cable ducts,
use of standard communication lines, e. g. J-Y (St) Y with a diameter of 0.8 mm
existing lines (modernisation) with deviating cross-sections can be used in compliance
with the loop resistance.
Installation – protective measures
With suitable measures to protect against lightning, it has to be ensured that a voltage
!
of each 32 V DC is not to be exceeded at the connections a, b, R, S, P.
PUK are front-door stations for the outdoor use.
They are characterized by a space saving design.
The housing is equipped with the win:clip system.
The front panel is made of 3 mm thick aluminium or stainless steel.
Universal installation: flush-mount or cavity wall.
TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88
FAX: +49 (0) 41 94/ 9 88 129 Mail: info@tcsag.de
3
Scope of delivery
(to fix the device within the flush-mount box, 2 per button row)
Safety instructions
Intended use
Subject to technical changes.
PI_PUK-uk 1 A
11/2012