1 x Indoor station ISH3230: upper cover, lower cover, handset with handset cord
Product information
Instruction manual
Attention! Installation, mounting, commissioning and repair of electrical devices has to
!
be carried out only by qualified electricians, The current standard for the installation of
door communication systems must be observed!
When installing TCS:BUS systems, the general safety regulations for telecommunication
systems according to VDE 0800 must be observed. Inter alia:
 separated cabling of heavy and low current lines,
 minimum distance of 10 cm for common cabling,
 use of separators between heavy and low current lines in shared cable ducts,
 use of standard telecommunication lines, e.g. J-Y (St) Y with 0.8 mm diameter,
 existing lines (modernisation) with deviating cross sections can be used in compliance
with the loop resistance.
Installation – protective measures
With suitable requirements to protect against lightning, it has to be ensured that a volt-
!
age of each 32 V DC is not exceeded at the connections a, b, P, E.
 ISH3230 are door telephones for duplex communication with handset for the TCS:BUS.
 They are suitable for the operation in TCS audio systems and combined audio / video
systems in the object area.
 They are suitable for surface-mount (installation via flush-mounted socket) or desktop
mount with desktop accessory ZIT3030-0010.
 3-wire technique necessary!
 The indoor station ISH3230 must not be used in call systems according to DIN VDE
0834 and EN50134.
 According to DIN 77800, a separate safeguard for emergency call has to be in-
stalled.
 A system equipped with an indoor station ISH3230 is not an emergency call system
!
according to the above mentioned standards.
 The indoor station ISH3230 must not be used in life-saving or life-sustaining sys-
tems.
 Further the combination of system parts which fulfill the above mentioned standards
is not permitted.