Technology Messages - Siemens SIMATIC ET 200SP Operating Instructions Manual

Technology module
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

Operating errors
1107 SecureDisplay failure
1111 DQ short-circuit to ground
9.4.2

Technology messages

Table 9-1
Technology messages
Technology messages
2000 Technological error
2001 Timeout waiting for stability
2002 Trace error
2003 Initial zero setting (Page 63) not
possible
2004 Trace memory full
Reboot after voltage recovery
Download error
2007 firmware file invalid
2101 Risk of overfilling
2102 Coarse shut-off point already ex‐
ceeded
2103 No stability
2104 CPU in Stop
Technology module TM SIWAREX WP351 HF
Operating Instructions, 01/2020, A5E47521010-AA
Error
Description and remedy
code
1107
The calibratable main display (SIWAREX SecureDisplay on SIMATIC HMI) no
longer communicates with the electronic weighing system
● Check the wiring between the SIMATIC HMI and the CPU or the electronic
weighing system and the SIMATIC controller.
● Check the IP addresses of the network components
1111
Error at digital outputs (short-circuit to ground)
Error code
Description and remedy
2000
Group message, at least one technology message is present
2001
Taring, zero setting, post dosing or check weighing was not possi‐
ble because stability was not reached during the stability waiting
time. Check the stability criteria and the stability waiting time in
DR03 and adjust the parameters as necessary. Check the scale
mechanics for strong fluctuations / disturbances that prevent sta‐
bility.
2002
The set recording cycle for tracing cannot be processed. Set a
slower recording rate (Page 75) in DR07.
2003
The weight of the initial zero setting is out of range.
2004
The trace recording has been aborted because the internal trace
memory is full.
2005
Diagnostic message for regular restart.
2006
A FW update was aborted or rejected, e.g. because a FW update is
already running or communication with the S7 controller was inter‐
rupted.
2007
FW update file (*.upd) was rejected because it is invalid. The FW
update file is not suitable for the electronic weighing system or is
defective, e.g. implausible length, structure, checksum or signature.
2101
Current parameter assignment would lead to overfilling of the scale
during dosing.
● Check the specified set point in DR20 or the limits for taring /
zero setting in DR03 and DR25.
2102
The current weight is already above the coarse shut-off point. Rem‐
edy: Adjust set point or empty scale.
2103
Required stability not present the dosing process.
2104
The electronic weighing system is not in stand-alone mode, the
SIMATIC CPU is in STOP state and a dosing command has been
issued. Remedy: Put the SIMATIC CPU in RUN state or activate the
stand-alone mode of the electronic weighing system.
CAUTION: Ensure the safety of the system before activating stand-
alone mode because the electronic weighing system activates dos‐
ing elements, if necessary, despite the stopped SIMATIC CPU.
Interrupts/diagnostic messages
9.4 Operating errors
131