Siemens SIMATIC ET 200SP Operating Instructions Manual page 113

Technology module
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

Com‐
Command
mand
code
82
Automatic calibration
83
Check calibration
907
Set impedance reference The currently measured impedance value (DR30) is transferred to
910
Trigger for monitoring of
Modbus communication
Table 6-4
Protocol commands, statistics, logbook
Com‐
Command
mand
code
401
Generate protocol
405
Erase protocols
440
Erase log book
442
Reset statistical data
443
Delete drag indicator
444
Reset counter "cycles of
operation - xCoarse feed"
445
Reset counter "cycles of
operation - coarse feed"
446
Reset counter "cycles of
operation - fine feed"
Table 6-5
Trace commands
Com‐
Command
mand
code
451
Trace ON
452
Trace OFF
453
Single trace element
454
Erase trace memory
Technology module TM SIWAREX WP351 HF
Operating Instructions, 01/2020, A5E47521010-AA
Description
Calculating the scale characteristic curve based on the load cell pa‐
rameters from DR10. The calculated characteristic curve is entered
directly in DR03 and DR04, and thus activated immediately after exe‐
cuting the command. The scale must be empty when the command is
executed. The accuracy of a scale that is automatically calibrated de‐
pends heavily on the mechanical setup!
The command calculates the theoretical digital values in relation to the
calibration weights using the load cell parameters from DR10 and the
calibration weights 1 to 4 from DR03. The output of these theoretical
digits is made in DR04. The function can be used to compare the cali‐
bration digits in DR03 that were determined during a calibration with
calibration weights (commands 61 to 64) with the theoretically expec‐
ted digits.
DR10 as impedance reference.
Starts time-based monitoring of Modbus communication
Description
Log current parameters relevant to the calibration
Delete all logs
Delete the logbook. Only permitted in non-calibrated state.
Deletes statistical data record DR39
Resets the drag indicator DR38
Deletes the cycle counter of the extra coarse signal
Deletes the cycle counter of the coarse signal
Deletes the cycle counter of the fine signal
Description
Start cyclic trace recording
Stop trace recording
Single recording (current state)
Delete trace recording
Parameter assignment/addressing
6.31 Commands
Write protec‐
tion
P
Write pro‐
tection
P
P
Write pro‐
tection
113

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tm siwarex wp351 hf

Table of Contents