Siemens SIMATIC ET 200SP Equipment Manual
Hide thumbs Also See for SIMATIC ET 200SP:

Advertisement

Quick Links

Edition
11/2022
EQUIPMENT MANUAL
SIMATIC
ET 200SP
CPU 1512SP-1 PN
6ES7512-1DM03-0AB0
support.industry.siemens.com

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC ET 200SP

  • Page 1 Edition 11/2022 EQUIPMENT MANUAL SIMATIC ET 200SP CPU 1512SP-1 PN 6ES7512-1DM03-0AB0 support.industry.siemens.com...
  • Page 2 Introduction Safety instructions SIMATIC Product overview ET 200SP CPU 1512SP-1 PN Wiring (6ES7512-1DM03-0AB0) Interrupts, error messages, diagnostics and system alarms Equipment Manual Technical specifications Dimension drawing 11/2022 A5E33591411-AE...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Table of contents Introduction............................ET 200SP Documentation Guide..................1.1.1 Information classes ET 200SP.................... 1.1.2 SIMATIC Technical Documentation..................Safety instructions..........................10 Security information......................10 Product overview..........................11 New functions........................11 Hardware properties......................12 Firmware functions......................15 Operating and display elements..................19 3.4.1 Front view of the module with BusAdapter................
  • Page 5: Introduction

    Industry Mall The Industry Mall is the catalog and order system of Siemens AG for automation and drive solutions on the basis of Totally Integrated Automation (TIA) and Totally Integrated Power (TIP).
  • Page 6: 200Sp Documentation Guide

    This arrangement enables you to access the specific content you require. You can download the documentation free of charge from the Internet (https://support.industry.siemens.com/cs/ww/en/view/109742709). Basic information The System Manual describes in detail the configuration, installation, wiring and commissioning of the SIMATIC ET 200SP distributed I/O system.
  • Page 7: Simatic Technical Documentation

    Product Information takes precedence over the device and system manuals. You can find the latest Product Information on the ET 200SP distributed I/O system on the Internet. (https://support.industry.siemens.com/cs/de/en/view/73021864) Manual Collection ET 200SP The Manual Collection contains the complete documentation on the SIMATIC ET 200SP distributed I/O system gathered together in one file.
  • Page 8 Online Support: Industry Online Support International https://support.industry.siemens.com/cs/ww/en/view/109742705 Watch this short video to find out where you can find the overview directly in Siemens Industry Online Support and how to use Siemens Industry Online Support on your mobile device: Quick introduction to the technical documentation of automation products per video ( https://support.industry.siemens.com/cs/us/en/view/109780491...
  • Page 9 Introduction 1.1 ET 200SP Documentation Guide You can find the application examples on the Internet. (https://support.industry.siemens.com/cs/ww/en/ps/ae) CPU 1512SP-1 PN (6ES7512-1DM03-0AB0) Equipment Manual, 11/2022, A5E33591411-AE...
  • Page 10: Safety Instructions

    Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 11: Product Overview

    Product overview New functions This section contains an overview of the most important new firmware functions of the CPU compared to the predecessor CPU (V2.9). New functions of the CPU in firmware version V3.0 New functions Applications Customer benefits Communication of the CPU Network Management Protocol A simple configuration option is available for Can be enabled/disabled in the CPU proper­...
  • Page 12: Hardware Properties

    .csv file for a long time (hours, days, of time etc.) Reference You can find an overview of all new functions, improvements and revisions in the respective firmware versions on the Internet (https://support.industry.siemens.com/cs/ww/en/view/109478459). Hardware properties Article number 6ES7512-1DM03-0AB0 CPU 1512SP-1 PN (6ES7512-1DM03-0AB0) Equipment Manual, 11/2022, A5E33591411-AE...
  • Page 13 CPU. • ET 200SP System Manual (https://support.industry. siemens. com/cs/ww/en/view/58649­ 293) Standalone CPU You can also use the CPU 1512SP-1 PN in the distributed I/O system ET 200SP as a "central system"...
  • Page 14 The CPU is delivered without a BusAdapter. You can find the article numbers of the supported BusAdapters in the "Accessories/spare parts" section of the ET 200SP distributed I/O system (https://support.industry.siemens.com/cs/ww/en/view/58649293) system manual. CPU 1512SP-1 PN (6ES7512-1DM03-0AB0) Equipment Manual, 11/2022, A5E33591411-AE...
  • Page 15: Firmware Functions

    3.3 Firmware functions NOTE You must provide covers for unused BusAdapter interfaces. You can find the article no. of the cover in the ET 200SP System Manual (https://support.industry.siemens.com/cs/ww/en/view/58649293) in the "Accessories/spare parts" section. Firmware functions Functions The CPU supports the following functions:...
  • Page 16 OPC UA With OPC UA, you can exchange data via an open and Communication function manual manufacturer-neutral communication protocol. (https://support.industry.siemens. The CPU can act as OPC UA server. The CPU acting as the com/cs/ww/en/view/59192925) OPC UA server can communicate with OPC UA clients.
  • Page 17 Additional information The devices receive this data at both ring ports so that PROFINET function manual there is no reconfiguration time. (https://support.automation.siemens. com/WW/view/en/49948856) Shared device The "Shared device" function allows you to divide the modules or submodules of an IO device up among differ­...
  • Page 18 – SCARA Integrated closed-loop con­ • PID Compact (continuous PID controller) PID control function manual trol functionality (https://support.industry.siemens. • PID 3Step (step controller for integrating actuators) com/cs/ww/en/view/108210036) • PID Temp (temperature controller for heating and cooling with two separate actuators)
  • Page 19: Operating And Display Elements

    Product overview 3.5 Mode switch Operating and display elements 3.4.1 Front view of the module with BusAdapter The figure on the left shows the CPU 1512SP‑1 PN including a plugged BA 2xRJ45 BusAdapter. The figure on the right shows a separate view of the BA 2xRJ45 BusAdapter. ①...
  • Page 20 Product overview 3.5 Mode switch The following table shows the position of the switch and the corresponding meaning. Table 3-1  Mode switch settings Position Meaning Explanation RUN mode The CPU is executing the user program. STOP STOP mode The user program is not being executed. MRES Memory reset Position for CPU memory reset.
  • Page 21: Wiring

    Wiring This section provides information on the pin assignment of the individual interfaces and the block diagram of the CPU 1512SP‑1 PN. 24 V DC supply voltage (X80) The connector for the supply voltage is plugged in when the CPU ships from the factory. The following table shows the signal names and the descriptions of the pin assignment of the 24 V DC supply voltage.
  • Page 22 Receive data + Transmit data + Shielding ① Reference You can find additional information on the topics of "Connecting the CPU" and "Accessories/spare parts" in the system manual ET 200SP distributed I/O system (https://support.automation.siemens.com/WW/view/en/58649293). CPU 1512SP-1 PN (6ES7512-1DM03-0AB0) Equipment Manual, 11/2022, A5E33591411-AE...
  • Page 23 Wiring Assignment of the MAC addresses The MAC address is a globally unique device identifier that is assigned to each PROFINET device in the factory. Its 6 bytes are divided into 3 bytes for the manufacturer ID and 3 bytes for the device ID (serial number). The front of the CPU 1512SP‑1 PN is lasered with the MAC address of the PROFINET interface.
  • Page 24 Wiring Block diagram The following figure shows the block diagram of the CPU 1512SP‑1 PN. ① PROFINET switch PROFINET interface X1 Port 1 ② Electronics PROFINET interface X1 Port 2 ③ Backplane bus interface PROFINET interface X1 Port 3 ④ Internal supply voltage 24 V DC supply voltage ⑤...
  • Page 25: Interrupts, Error Messages, Diagnostics And System Alarms

    The status and error displays of the CPU 1512SP‑1 PN are described below. You will find additional information on "Interrupts" in the STEP 7 online help. You can find additional information on the topics of "Diagnostics" and "System alarms" in the Diagnostics (https://support.automation.siemens.com/WW/view/en/59192926) function manual. Status and error display of the CPU LED displays The figure below shows the LED displays of the CPU 1512SP‑1 PN and the BA 2xRJ45...
  • Page 26 Interrupts, error messages, diagnostics and system alarms 5.1 Status and error display of the CPU table shows the meaning of the various combinations of colors for the POWER, RUN/STOP, ERROR and MAINT LEDs. Table 5-1  Meaning of the LEDs POWER RUN/STOP LED ERROR MAINT Meaning...
  • Page 27 Interrupts, error messages, diagnostics and system alarms 5.1 Status and error display of the CPU POWER RUN/STOP LED ERROR MAINT Meaning Startup (CPU booting) LED lit green LED flashes red LED flashes yellow LED flashes Test of LEDs during startup, inserting a yellow/green module.
  • Page 28: Technical Specifications

    Technical specifications The following table shows the technical specifications as of 11/2022. You will find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/ww/en/pv/6ES7512-1DM03-0AB0/td?dl=en). Article number 6ES7512-1DM03-0AB0 General information   Product type designation CPU 1512SP-1 PN HW functional status...
  • Page 29 Technical specifications Article number 6ES7512-1DM03-0AB0 Number of slots for SIMATIC memory card SIMATIC memory card required Work memory   • integrated (for program) 400 kbyte integrated (for data) 2 Mbyte • Load memory   • Plug-in (SIMATIC Memory Card), max. 32 Gbyte Backup  ...
  • Page 30 Technical specifications Article number 6ES7512-1DM03-0AB0 • Number of asynchronous error OBs • Number of synchronous error OBs • Number of diagnostic alarm OBs Nesting depth   • per priority class Counters, timers and their retentivity   S7 counter   • Number 2 048 Retentivity...
  • Page 31 Technical specifications Article number 6ES7512-1DM03-0AB0 per integrated IO subsystem   – Inputs (volume) 8 kbyte Outputs (volume) 8 kbyte – per CM/CP   – Inputs (volume) 8 kbyte – Outputs (volume) 8 kbyte Subprocess images   • Number of subprocess images, max. Address space per module  ...
  • Page 32 Technical specifications Article number 6ES7512-1DM03-0AB0 • Number Clock synchronization   supported • • to DP, master Yes; Via CM DP module • to DP, slave Yes; Via CM DP module • in AS, master • in AS, slave on Ethernet via NTP •...
  • Page 33 Technical specifications Article number 6ES7512-1DM03-0AB0 – Number of connectable IO Devices for RT, max. – of which in line, max. – Number of IO Devices that can be sim­ 8; in total across all interfaces ultaneously activated/deactivated, max. – Number of IO Devices per tool, max. Updating times The minimum value of the update time also –...
  • Page 34 Technical specifications Article number 6ES7512-1DM03-0AB0 • RS 485 Yes; Via CM DP module • Number of ports Protocols   • PROFIBUS DP master • PROFIBUS DP slave • SIMATIC communication PROFIBUS DP master   • Number of connections, max. 48; Of which 4 each reserved for ES and HMI Number of DP slaves, max.
  • Page 35 Technical specifications Article number 6ES7512-1DM03-0AB0 – MRP interconnection, supported Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 – MRPD Yes; Requirement: IRT – Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD Number of stations in the ring, max. –...
  • Page 36 Technical specifications Article number 6ES7512-1DM03-0AB0 – Number of connections, max. – Number of nodes of the client inter­ 1 000 faces, max. – Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_­ ReadList/OPC_UA_WriteList, max. – Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max.
  • Page 37 Technical specifications Article number 6ES7512-1DM03-0AB0 – Number of server interfaces, max. 10 of each "Server interfaces" / "Companion spe­ cification" type and 20 of the type "Reference namespace" Number of nodes for user-defined serv­ 15 000 – er interfaces, max. • Alarms and Conditions Number of program alarms –...
  • Page 38 Technical specifications Article number 6ES7512-1DM03-0AB0 Interrupts/diagnostics/status information   Diagnostics indication LED   • RUN/STOP LED ERROR LED • • MAINT LED • Monitoring of the supply voltage (PWR- LED) • Connection display LINK TX/RX Supported technology objects   Motion Control Yes;...
  • Page 39 Technical specifications Article number 6ES7512-1DM03-0AB0 Altitude during operation relating to sea level   • Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual configuration / header   configuration / programming / header  ...
  • Page 40 Technical specifications Article number 6ES7193-6AR00-0AA0 • Number of RJ45 ports • Number of SCRJ ports • Number of LC ports Cable length   – Cu conductors 100 m Ambient conditions   Ambient temperature during operation   • horizontal installation, min. -30 °C •...
  • Page 41 General technical specifications You can find information on the general technical specifications, such as standards and approvals, electromagnetic compatibility, protection class, etc., in the system manual ET 200SP distributed I/O system (https://support.automation.siemens.com/WW/view/en/58649293). CPU 1512SP-1 PN (6ES7512-1DM03-0AB0) Equipment Manual, 11/2022, A5E33591411-AE...
  • Page 42: Dimension Drawing

    Dimension drawing This section contains a dimension drawing of the module mounted on a mounting rail. Always observe the specified dimensions for installation in cabinets, control rooms, etc. Dimension drawing of the CPU 1512SP-1 PN Figure A-1  Dimension drawing CPU 1512SP-1 PN CPU 1512SP-1 PN (6ES7512-1DM03-0AB0) Equipment Manual, 11/2022, A5E33591411-AE...

This manual is also suitable for:

Cpu 1512sp-1 pn

Table of Contents