Parameter assignment/addressing
6.31 Commands
Table 6-6
Totalization commands
Com‐
Command
mand
code
651
Delete total 1
652
Delete total 2
653
Log and delete total 1
Table 6-7
Display changeover for DR34 and SecureDisplay
Com‐
Command
mand
code
701
High resolution on
705
Display Tare Process
706
Display current gross
weight
710
Display standard weight
714
Net process weight
715
Gross process weight
716
Gross weight after F1
721
Display single set point
722
Display total set point
725
Display deviation set
point/actual value
726
Display mean value
727
Display standard devia‐
tion
728
Display number of weigh‐
ings
771
Display Totalizer 1
772
Display Totalizer 2
801
Display Current Restric‐
tion Code
802
Display weighing range
information
860
Hide SecureDisplay
114
Description
Deletes total 1 in DR30 (not possible for THW in OIML mode)
Deletes total 2 in DR30
Logs total 1 in alibi memory and then deletes it (THW mode)
Description
Activate high resolution (factor 10) of the weight value on the main dis‐
play (DR34) and the SecureDisplay for 5 s.
Display current tare weight on the main display (DR34) and the Secure‐
Display.
Display current gross weight in SecureDisplay and DR34
Display standard gross/net weight display on the main display (DR34)
and the SecureDisplay.
Display currently set point setting from DR20 on the main display
(DR34) and the SecureDisplay for 5 seconds.
Display currently total set point setting from DR21 on the main display
(DR34) and the SecureDisplay for 5 seconds.
Display current difference between set point and actual value
Display current mean value (from DR39)
Display standard deviation (from DR39)
Display current number of weighings (from DR39)
Display Totalizer 1 from DR30
Display Totalizer 2 from DR30
Display restriction code set in DR3 on the main display (DR34) and the
SecureDisplay for 5 seconds (command only relevant for scales requir‐
ing official calibration).
Show weighing range information (min, max, resolution) in SecureDis‐
play for 10 seconds (command only relevant for scales requiring official
calibration).
Places SecureDisplay in the background of the HMI (command only
relevant for scales requiring official calibration).
Technology module TM SIWAREX WP351 HF
Operating Instructions, 01/2020, A5E47521010-AA
Write pro‐
tection
Write pro‐
tection