Siemens SIMATIC ET 200SP Operating Instructions Manual page 45

Technology module
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

3. Set the associated command trigger [trigger] to "true".
4. Evaluate the associated status bits:
Command in progress. [inProgress]
Command finished without error. [finishedOk]
Command rejected or finished with error. [finishedError] [errorCode (Page 133)]
[errorAddInfo (Page 137)] You can find a list of data and operating errors in
section Operating errors (Page 130).
Figure 6-4
Example: Configuring calibration weight 1
You want to set the value 12.5 for the parameter Calibration weight 1 [calibrationWeight1].
1. Switch on service mode by entering the command code 1 for the "code" parameter in the
"Command1" command mailbox.
2. Set the associated command trigger "trigger" to "true".
⇒ The "Wrench LED" on the electronic weighing system flashes orange.
3. Read DR03 by entering the command code 2003 for the "code" parameter in the
"Command1" command mailbox.
4. Set the associated command trigger "trigger" to "true".
⇒ All current data from DR03 is present in the interface DB.
5. In DR03, enter the value 12.5 for calibration weight 1 [calibrationWeight1].
Technology module TM SIWAREX WP351 HF
Operating Instructions, 01/2020, A5E47521010-AA
Command mailboxes Command1, Command2 and Command3
Parameter assignment/addressing
6.2 TIA Portal user program
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tm siwarex wp351 hf

Table of Contents